MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1183/09031936.06.00130904

Медицинская библиотека · The European respiratory journal · 2006

Can heart rate variation rule out sleep-disordered breathing in heart failure?

Vazir A, Dayer M, Hastings P C, McIntyre H F, Henein M Y, Poole-Wilson P A, Cowie M R, Morrell M J, Simonds A K

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

In patients with obstructive sleep apnoea (OSA), the very low frequency power spectral density index (VLFI) derived from analysis of heart rate correlates with the severity of obstructive apnoeas. VLFI is also associated with Cheyne-Stokes respiration/central sleep apnoea (CSR/CSA) in congestive heart failure (CHF). The present authors have tested the hypothesis that per cent VLFI, derived from a standard Holter ECG recording, can be used to detect the presence of OSA and CSR/CSA in patients with mild-to-moderate CHF. In total, 60 CHF patients underwent polysomnography with monitoring of heart rate. Data from 33 patients were analysed for per cent VLFI. Of the 60 patients, 27 were excluded due to atrial fibrillation, extensive pacing or frequent ventricular extra systoles. Receiver operator characteristic curves were constructed to establish the per cent VLFI that would optimally identify the presence or absence of sleep-disordered breathing. Using an apnoea-hypopnoea index>20 events.h-1 and setting the per cent VLFI at 2.23% yielded a sensitivity of 85%, specificity of 65%, positive predictive value of 61% and a negative predictive value of 87%. The latter increased to 100% when using an apnoea-hypopnoea cut-off of 30 events.h-1. In conclusion, these results suggest that spectral analysis of heart rate may be useful as a "rule-out test" for sleep-disordered breathing in patients with mild-to-moderate congestive heart failure.

Для цитирования: Vazir A, Dayer M, Hastings P C, McIntyre H F, Henein M Y, Poole-Wilson P A, Cowie M R, Morrell M J, Simonds A K. Can heart rate variation rule out sleep-disordered breathing in heart failure?. The European respiratory journal. 2006. DOI: 10.1183/09031936.06.00130904.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.