OBJECTIVE

The predictive value of electrophysiologic visual testing in Creutzfeldt-Jakob disease (CJD) was investigated, and the retinal pathologic findings in three cases are reported.

BACKGROUND

The fatal prognosis of CJD, its transmissibility, and the lack of treatment make early diagnosis essential in averting human-to-human transmission. Electroretinogram and visual evoked potentials have been studied in few cases of CJD.

METHODS

A visual electrophysiologic examination was performed in 41 consecutive patients referred with suspected CJD. The disease had been diagnosed in 24 patients (CJD group; 15 were confirmed neuropathologically and 9 by clinicolaboratory methods in accordance with diagnostic criteria). The remaining 17 patients were diagnosed with other neurologic disorders, and served as a control group.

RESULTS

Flash electroretinogram revealed a significant decrease in the amplitude of the B1 wave (<60 microV) and the B/A ratio (<2) in the CJD group compared with those in the control group. Flash visual evoked potentials revealed no significant difference in latency, but amplitude was increased (>10 microV) in the CJD group, especially in patients with myoclonus.

CONCLUSIONS

The visual electrophysiologic abnormalities provide an interesting noninvasive diagnostic tool in idiopathic CJD. The B1-wave decrease is closely correlated with the outer plexiform layer abnormalities observed on neuropathologic examination.

Для цитирования: de Seze J, Hache J C, Vermersch P, Arndt C F, Maurage C A, Pasquier F, Laplanche J L, Ruchoux M M, Leys D, Destée A, Petit H. Creutzfeldt-Jakob disease: neurophysiologic visual impairments.. Neurology. 1998. DOI: 10.1212/wnl.51.4.962.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.