MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/molecules28227525

Медицинская библиотека · Molecules (Basel, Switzerland) · 2023

In Situ Formation of a Relatively Transparent Ion-Associate Liquid Phase from an Aqueous Phase and Its Application to Microextraction/High-Performance Liquid Chromatography-Fluorescence Detection of Bisphenol A in Water.

Hata Noriko, Takahashi Seira, Osada Sachiko, Katagiri Sakura, Naruse Mayumi, Igarashi Akane, Sazawa Kazuto, Taguchi Shigeru, Kuramitz Hideki

СтатьяПеревод в очереди

Аннотация

The design of a simple approach enabling the detection of bisphenol A (BPA) in water samples without the need for large amounts of solvents is of utmost importance. This paper reports a simple method for the separation, concentration, and quantification of BPA in water samples using high-performance liquid chromatography with fluorescence detection (HPLC-FLD) after its microextraction into an in situ formed organic ion-associate (IA) liquid phase (LP). Novel IA phase components without conjugated double bonds, such as benzene rings, were investigated. Ethylhexyloxypropylamine hydrochloride and sodium dodecyl sulfate solutions were added to the water samples to form IAs. The aqueous phase and ion-associate liquid phase (IALP) were separated by centrifugation. The aqueous phase was removed, and the liquid phase was recovered and measured using HPLC-FLD or HPLC-electrochemical detection (ECD). The concentrated phase (IALP) had a relatively low viscosity and could be injected directly into the chromatograph without dissolving it in organic solvents. The detection limits for BPA by HPLC-FLD and HPLC-ECD were 0.009 and 0.3 µg L-1, respectively.

Для цитирования: Hata Noriko, Takahashi Seira, Osada Sachiko, Katagiri Sakura, Naruse Mayumi, Igarashi Akane, Sazawa Kazuto, Taguchi Shigeru, Kuramitz Hideki. In Situ Formation of a Relatively Transparent Ion-Associate Liquid Phase from an Aqueous Phase and Its Application to Microextraction/High-Performance Liquid Chromatography-Fluorescence Detection of Bisphenol A in Water.. Molecules (Basel, Switzerland). 2023. DOI: 10.3390/molecules28227525.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.