MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/europace/eus250

Медицинская библиотека · Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2012

Prolonged burst as a new method for cardioverter-defibrillator testing.

Lukl Jan, Marek Dan, Bulava Alan, Fedorco Marián, Schneiderka Petr, Táborsky Milos, Zapletalová Jana

СтатьяРандомизированное исследованиеПеревод в очереди

Аннотация

AIM: To find out whether it is possible to anaesthetize patients safely without analgesia and sedation, using burst pacing prolonged until the patient becomes unconscious.

METHODS

One hundred and four patients undergoing implantation or reimplantation of a cardioverter-defibrillator were included. Patients randomized into Group B underwent prolonged burst pacing without analgesia and sedation. Patients in Group T underwent a T-wave shock under analgesia and sedation. Blood samples for measurement of serum neuron-specific enolase were taken before surgery and 6, 24, and 48 h after the procedure.

RESULTS

From the 104 patients, 51 were randomly assigned to Group B and 53 to Group T. Four patients from Group B were switched to Group T (ventricular fibrillation not induced by burst pacing). The clinical characteristics of both groups were similar. The mean total time of cardiac arrest was significantly longer in Group B (23.0 ± 4.4 s, median 22.7) vs. Group T (10.3 ± 3.0 s, median 10.0), P < 0.0001 (Mann-Whitney U-test). The effectiveness of both induction methods was similar (92.1% in Group B and 100% in Group T). The mean neuron-specific enolase levels after 6, 24, and 48 h were similar in Groups B and T (13.1 ± 6.3 and 11.6 ± 5.8 mg/L, 14.5 ± 7.5 and 13.4 ± 6.0 mg/L, and 14.9 ± 5.9 and 12.2 ± 6.0 mg/L, respectively) as were these levels compared with baseline neuron-specificenolase levels (14.0 ± 5.9 and 13.4 ± 4.0 mg/L, respectively), P = NS for all.

CONCLUSION

Despite a longer time of total cardiac arrest, prolonged burst pacing appears to be a safe and effective method for induction of ventricular fibrillation during cardioverter-defibrillator testing, which enables omission of analgesia and sedation or general anaesthesia.

Для цитирования: Lukl Jan, Marek Dan, Bulava Alan, Fedorco Marián, Schneiderka Petr, Táborsky Milos, Zapletalová Jana. Prolonged burst as a new method for cardioverter-defibrillator testing.. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology. 2012. DOI: 10.1093/europace/eus250.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.