PURPOSE: To present a new technique using the recently introduced Enduragen(®) material (Tissue Science Laboratories) as a patch graft for exposed ocular implants.

METHODS

A retrospective, interventional, non-comparative case series of 3 patients who had Enduragen patch grafts for the closure of Tenon's capsule and conjunctiva over exposed ocular implants. Medical records were reviewed and the following parameters were collected: age, gender, indication for surgery, type of surgery, laterality, type of orbital implant, complications after repair and length of follow-up.

RESULTS

Three patients were identified, 2 males and 1 female. One patient had a secondary quad-motility implant with supertemporal exposure. The second patient had a secondary implant with a fistula at the lateral aspect of the socket. The third patient had a centrally exposed primary hydroxyapatite implant. All patients received Enduragen patch grafts to cover the implant. Follow up ranged from 40 to 43 months (mean, 41.3 months; SD, ± 1.5). None of the 3 patients had any signs of implant re-exposure at the time of the last post-operative visit. There were no intra-operative or early complications observed.

CONCLUSIONS

This consecutive case series suggests that Enduragen could be used as a safe and effective patch graft for exposed ocular implants. However, a larger prospective study with longer follow-up would be useful in further defining the indications and limitations of the Enduragen patch graft for the treatment of exposed orbital implants.

Для цитирования: Wu Albert Y, Vagefi M Reza, Georgescu Dan, Burroughs John R, Anderson Richard L. Enduragen patch grafts for exposed orbital implants.. Orbit (Amsterdam, Netherlands). 2011. DOI: 10.3109/01676830.2011.558974.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.