MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/ccm.0b013e318232d8de

Медицинская библиотека · Critical care medicine · 2012

Use of the impedance threshold device improves survival rate and neurological outcome in a swine model of asphyxial cardiac arrest*.

Pantazopoulos Ioannis N, Xanthos Theodoros T, Vlachos Ioannis, Troupis Georgios, Kotsiomitis Evangelos, Johnson Elisabeth, Papalois Apostolos, Skandalakis Panagiotis

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To assess whether intermittent impedance of inspiratory gas exchange improves hemodynamic parameters, 48-hr survival, and neurologic outcome in a swine model of asphyxial cardiac arrest treated with active compression-decompression cardiopulmonary resuscitation.

DESIGN

Prospective, randomized, double-blind study.

SETTING

Laboratory investigation.

SUBJECTS: Thirty healthy Landrace/Large-White piglets of both sexes, aged 10 to 15 wks, whose average weight was 19 ± 2 kg.

INTERVENTIONS: At approximately 7 mins following endotracheal tube clamping, ventricular fibrillation was induced and remained untreated for another 8 mins. Before initiation of cardiopulmonary resuscitation, animals were randomly assigned to either receive active compression-decompression cardiopulmonary resuscitation plus a sham impedance threshold device (control group, n = 15), or active compression-decompression cardiopulmonary resuscitation plus an active impedance threshold device (experimental group, n = 15). Electrical defibrillation was attempted every 2 mins until return of spontaneous circulation or asystole.

MEASUREMENTS AND MAIN

RESULTS

Return of spontaneous circulation was observed in six (40%) animals treated with the sham valve and 14 (93.3%) animals treated with the active valve (p = .005, odds ratio 21.0, 95% confidence interval 2.16-204.6). Neuron-specific enolase and S-100 levels increased in the ensuing 4 hrs post resuscitation in both groups, but they were significantly elevated in animals treated with the sham valve (p < .01). At 48 hrs, neurologic alertness score was significantly better in animals treated with the active valve (79.1 ± 18.7 vs. 50 ± 10, p < .05) and was strongly negatively correlated with 1- and 4-hr postresuscitation neuron-specific enolase (r = -.86, p < .001 and r = -.87, p < .001, respectively) and S-100 (r = -.77, p < .001 and r = -0.8, p = .001) values.

CONCLUSIONS

In this model of asphyxial cardiac arrest, intermittent airway occlusion with the impedance threshold device during the decompression phase of active compression-decompression cardiopulmonary resuscitation significantly improved hemodynamic parameters, 24- and 48-hr survival, and neurologic outcome evaluated both with clinical and biochemical parameters (neuron-specific enolase, S-100).

Для цитирования: Pantazopoulos Ioannis N, Xanthos Theodoros T, Vlachos Ioannis, Troupis Georgios, Kotsiomitis Evangelos, Johnson Elisabeth, Papalois Apostolos, Skandalakis Panagiotis. Use of the impedance threshold device improves survival rate and neurological outcome in a swine model of asphyxial cardiac arrest*.. Critical care medicine. 2012. DOI: 10.1097/ccm.0b013e318232d8de.