MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.alcohol.2023.06.002

Медицинская библиотека · Alcohol (Fayetteville, N.Y.) · 2023

Is optic nerve sheath diameter diagnostic in methanol intoxication?

Sener Kemal, Cakır Adem, Altug Ertugrul, Korkut Semih, Güven Ramazan, Kapci Mücahit

СтатьяПеревод в очереди

Аннотация

BACKGROUND AND AIM: Methyl alcohol intoxication causes severe morbidity and mortality, especially in developing countries. Formic acid is formed as a result of methanol metabolism. Formic acid accumulation and inhibition of adenosine triphosphate synthesis result in ophthalmic issues. This study aimed to demonstrate that the optic nerve sheath diameter (ONSD) measurement is an accurate prognostic marker and can be helpful in the diagnosis of methanol intoxication.

MATERIALS AND

METHODS

This prospective study was conducted with 52 patients who were admitted to the emergency department after alcohol consumption and agreed to participate in the study. Age, gender, comorbid diseases, vital signs, ONSD ultrasonography measurements, hospitalization and discharge status, in-hospital mortality status, dialysis need, presence of visual impairment, blood gas parameters, respiratory status, time since alcohol intake, ethanol levels, urea levels, and creatinine levels were analyzed.

RESULTS

ROC curve analysis was performed to evaluate the predictive power of ONSD to diagnose methanol intoxication. The area under the curve was 0.857 for the cut-off value of 5.05 mm (95 % CI: 0.728-0.985; p < 0.001), with a sensitivity of 80.8 % and a specificity of 100 %. In the regression analysis performed to determine the prognostic value of the parameters in estimating mortality in methanol intoxication cases, an increase in ONSD (OR: 3.619; 95 % CI: 0.057-0.199; p = 0.001), an increase in lactate levels (OR: 5.653; 95 % CI: 0.040-0.085; p < 0.001), and increased duration after alcohol intake (OR: 2558; 95 % CI: 0.004-0.034; p = 0.014) were identified as independent predictors of mortality, but pH, HCO3, and base deficit levels were not significant predictors.

CONCLUSIONS

We believe that ONSD can be helpful for the differential diagnosis and prognosis of patients with suspected methanol toxicity who presented with alcohol intake.

Для цитирования: Sener Kemal, Cakır Adem, Altug Ertugrul, Korkut Semih, Güven Ramazan, Kapci Mücahit. Is optic nerve sheath diameter diagnostic in methanol intoxication?. Alcohol (Fayetteville, N.Y.). 2023. DOI: 10.1016/j.alcohol.2023.06.002.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.