Serum activin A does not predict ectopic pregnancy as a single measurement test, alone or as part of a multi-marker panel including progesterone and hCG.
Аннотация
BACKGROUND
To evaluate the diagnostic accuracy of activin A alone or in a multi-marker panel for the prediction of ectopic pregnancy (EP).
METHODS
A retrospective analysis was performed on a cohort of 289 women who presented to the emergency department (ED) with vaginal bleeding and/or abdominal pain/cramping and were diagnosed with EP, spontaneous abortion, or viable intrauterine pregnancy. Serum progesterone, hCG, and activin A concentrations were measured on the samples obtained in the ED. Statistical analysis was performed to determine the clinical utility of these biomarkers as single measurement and as a multi-marker panel test for ectopic pregnancy. Women ≥18 y with vaginal bleeding or abdominal pain/cramping.
RESULTS
Progesterone (<10 ng/ml), hCG (<6,699 IU/l), and activin A (<0.26 ng/ml) cutoffs were optimized by ROC analysis. These demonstrated sensitivities of 62.9%, 74.2%, and 59.6%, and specificities of 60.5%, and 63.0%, and 61.0% respectively for detecting EP. The multi-marker panel utilizing all three biomarkers had a sensitivity of 70% and specificity of 69%.
CONCLUSION
Serum activin A cannot be used as a single measurement or in a multi-marker panel with progesterone and hCG to predict EP.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.