MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/ueg2.70068

Медицинская библиотека · United European gastroenterology journal · 2025

An Interpretable Artificial Intelligence System for Crohn's Disease Ulcer Identification and Grading on Double-Balloon Enteroscopy Images.

Liu Qiuyuan, Xie Wanqing, Wang Aodi, Han Wei, Zhu Yaonan, Hu Jing, Liang Pengcheng, Wu Juan, Liu Xiaofeng, Yang Xiaodong, Zhang Baoliang, Zhu Nannan, Bai Bingqing, Mei Yiqing, Liang Zhen, Cheng Mingmei, Mei Qiao

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Crohn's disease (CD) is an incurable inflammatory bowel disease that can lead to a variety of complications and requires lifelong treatment. However, the diagnosis and management of Crohn's disease exhibit high rates of misdiagnosis and missed diagnoses, along with significant variability, among primary care facilities and novice endoscopists. Therefore, we established an interpretable artificial intelligence (AI) system using double-balloon enteroscopy to facilitate Crohn's disease ulcer identification and grading.

OBJECTIVE

To develop an interpretable AI system for the identification and grading of Crohn's disease ulcer images, offering bounding box localization for visual interpretability and factor-specific grading explanations for each ulcer to improve assessment performance.

METHODS

We constructed a region and grading model of individual ulcers based on the YOLO-v5 algorithm. By analyzing the predicted results of all ulcers in each image, the clinical interpretation for the screening and assessment of Crohn's disease ulcer images was further achieved. To evaluate the system, we prepared the training and validation datasets (17,036 double-balloon enteroscopy images, 558 patients) and further collected a test cohort (2018 images, 70 patients) and an external validation set. A further reader study was conducted on the internal test set in which nine endoscopists participated to evaluate the auxiliary effectiveness of the explainable system.

RESULTS

The Crohn's disease ulcer image detection sensitivity and area under the curve (AUC) were 91.8% and 0.949. The accuracies in assessing the severity of Crohn's disease ulcer images on three factors (size/ulcerated surface/depth) were 94.1%/92.5%/93.0%, respectively. With the system's support of visualized and analyzable predictions, junior endoscopists improved their Crohn's disease ulcer image recognition sensitivity by 12.7% and their accuracy and consistency of severity assessment by 26% and 27.4%.

CONCLUSION

The AI system outperformed general endoscopists in approaching expert-level proficiency in Crohn's disease ulcer identification and assessment. Its transparency in decision-making facilitated integration into clinical workflows, enhancing trust and consistency among endoscopists.

Для цитирования: Liu Qiuyuan, Xie Wanqing, Wang Aodi, Han Wei, Zhu Yaonan, Hu Jing, Liang Pengcheng, Wu Juan, Liu Xiaofeng, Yang Xiaodong, Zhang Baoliang, Zhu Nannan, Bai Bingqing, Mei Yiqing, Liang Zhen, Cheng Mingmei, Mei Qiao. An Interpretable Artificial Intelligence System for Crohn's Disease Ulcer Identification and Grading on Double-Balloon Enteroscopy Images.. United European gastroenterology journal. 2025. DOI: 10.1002/ueg2.70068.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.