MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.juro.2011.09.058

Медицинская библиотека · The Journal of urology · 2011

Accuracy of sentinel lymph node biopsy for inguinal lymph node staging of penile squamous cell carcinoma: systematic review and meta-analysis of the literature.

Sadeghi Ramin, Gholami Hassan, Zakavi Seyed Rasoul, Kakhki Vahid Reza Dabbagh, Tabasi Kamyar Tavakkoli, Horenblas Simon

СтатьяМетаанализПоддержка исследования: вне правительства СШАСистематический обзорПеревод в очереди

Аннотация

PURPOSE: Sentinel lymph node biopsy is emerging as a promising method for inguinal lymph node staging of penile squamous cell carcinoma. In the current systematic review we evaluated the accuracy of sentinel lymph node biopsy for inguinal lymph node staging of penile squamous cell carcinoma and studied possible influential factors.

MATERIALS AND

METHODS

MEDLINE®, Scopus®, ISI®, Ovid SP®, Springer, ScienceDirect® and Google™ Scholar were searched by the key words "(penile OR penis) AND sentinel". No date or language limitation was imposed on the search and meeting abstracts were not excluded from analysis. A random effects model was used for statistical pooling.

RESULTS

A total of 17 studies suitable for meta-analysis were detected. Three articles had 2 different subgroups of patients and each subgroup was considered as a separate study. Overall 18 studies (including the subgroups) were used for detection rate meta-analysis and 19 for sensitivity meta-analysis. The pooled detection rate was 88.3% (95% CI 81.9-92.6). Pooled detection rate of 90.1% (95% CI 83.6-94.1) was calculated for the studies using blue dye and radiotracer. The pooled sensitivity was 88% (95% CI 83-92). The highest pooled sensitivity (92% [95% CI 86-96]) was in the studies using radiotracer and blue dye, and recruiting only cN0 cases.

CONCLUSIONS

Sentinel lymph node mapping in penile squamous cell carcinoma is a method with a high detection rate and sensitivity. Using radiotracer and blue dye for sentinel lymph node mapping and including only cN0 disease ensures the highest detection rate and sensitivity.

Для цитирования: Sadeghi Ramin, Gholami Hassan, Zakavi Seyed Rasoul, Kakhki Vahid Reza Dabbagh, Tabasi Kamyar Tavakkoli, Horenblas Simon. Accuracy of sentinel lymph node biopsy for inguinal lymph node staging of penile squamous cell carcinoma: systematic review and meta-analysis of the literature.. The Journal of urology. 2011. DOI: 10.1016/j.juro.2011.09.058.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.