Disinfection of vascular catheter connectors that are protected by antiseptic caps is unnecessary.

Fillman Kelsey M, Ryder Jonathan H, Brailita Daniel M, Rupp Mark E, Cavalieri R Jennifer, Fey Paul D, Lyden Elizabeth R, Hankins Richard J

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

Determination of whether vascular catheter disinfecting antiseptic-containing caps alone are effective at decreasing microbial colonization of connectors compared to antiseptic-containing caps plus a 5-second alcohol manual disinfection.

SETTING

The study was conducted in a 718-bed, tertiary-care, academic hospital.

PATIENTS: A convenience sample of adult patients across intensive care units and acute care wards with peripheral and central venous catheters covered with antiseptic-containing caps.

METHODS

Quality improvement study completed over 5 days. The standard-of-care group consisted of catheter connectors with antiseptic-containing caps cleaned with a 5-second alcohol wipe scrub prior to culture. The comparison group consisted of catheter connectors with antiseptic-containing caps without a 5-second alcohol wipe scrub prior to culture. The connectors were pressed directly onto blood agar plates and incubated. Plates were assessed for growth after 48-72 hours.

RESULTS

In total, 356 catheter connectors were cultured: 165 in the standard-of-care group, 165 in the comparison group, and 26 catheters connectors without an antiseptic-containing cap, which were designated as controls. Overall, 18 catheter connectors (5.06%) yielded microbial growth. Of the 18 connectors with microbial growth, 2 (1.21%) were from the comparison group, 1 (0.61%) was from the standard-of-care group, and 15 were controls without an antiseptic-containing cap.

CONCLUSIONS

Bacterial colonization rates were similar between the catheter connectors cultured with antiseptic-containing caps alone and catheter connectors with antiseptic-containing caps cultured after a 5-second scrub with alcohol. This finding suggests that the use of antiseptic-containing caps precludes the need for additional disinfection.

Для цитирования: Fillman Kelsey M, Ryder Jonathan H, Brailita Daniel M, Rupp Mark E, Cavalieri R Jennifer, Fey Paul D, Lyden Elizabeth R, Hankins Richard J. Disinfection of vascular catheter connectors that are protected by antiseptic caps is unnecessary.. Infection control and hospital epidemiology. 2023. DOI: 10.1017/ice.2023.148.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.