m+Medelevator.RU
← Поиск публикаций
BMC cancer · 2026

Surface-guided radiation therapy combined with real-time position management-guided deep inspiratory breath-hold radiotherapy for left breast cancer.

СтатьяРандомизированное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Guo Hai-Liang, Xie Hua-Ying, Jiang Chun-Ling, Weng Can-Feng, Liao Guo-Ping, Zhu Gang-Feng, Song Yi-Peng, Xie Rui-Lian, Zhong Jing-Hua, Zhang Huai-Wen

Аннотация

BACKGROUND AND PURPOSE: To evaluate the efficacy of surface-guided radiation therapy (SGRT) combined with real-time position management (RPM)-guided deep inspiratory breath-hold (DIBH) radiotherapy for left breast cancer. MATERIALS AND METHODS: Twenty patients diagnosed with breast cancer, who underwent breast-conserving surgery and subsequent DIBH radiotherapy, were randomly assigned to two treatment groups: SGRT-guided (SGRT); and combined SGRT + RPM-guided (SGRT + RPM). Recorded setup and cone beam computed tomography (CBCT) validation execution Time (T1), Beam delivery time (T2). Residual vertical setup error (VRT Error), six-dimensional (6D) setup errors, and breath-hold error (BH Error) were obtained using breath hold CBCT. Correlations between BH Error and VRT Error were analyzed. Dose reconstruction was performed using velocity-generated adaptive CT to compute per-fraction and accumulated doses, with coefficient of variation (CV) analysis used to quantify interfractional dose variations in clinical target volume (CTV) and organs at risk (OARs). RESULTS: The mean (± SD) T1 and T2 times for the SGRT and SGRT + RPM groups were 452.53 ± 83.57 s vs. 299.58 ± 53.52 s (p < 0.05), and 147.85 ± 46.35 s vs. 135.3 ± 32.97 s (p > 0.05), respectively, with no statistical difference in 6D setup errors (p > 0.05). The SGRT group exhibited a mean BH Error that was 0.4 mm larger than that of the SGRT + RPM group, with a 0.7 mm reduction in stability. There was a correlation between BH Error and VRT Error in the SGRT group (r = 0.635, p < 0.05). Accumulated dose analysis revealed statistically significant decreases in CTV D98% and V95% in both groups (p < 0.05). However, maintained CTV coverage meeting clinical acceptability criteria (V95% ≥ 95%). The accumulated OARs doses demonstrated no significant differences compared with the planned doses (p > 0.05). There was no significant difference in CV values between the two groups (p > 0.05). CONCLUSION: The DIBH guided by SGRT + RPM simplify the radiotherapy workflow, improve the operation efficiency and breath-hold (BH) quality of patients. Simultaneously, it guaranteed alignment of the cumulative doses received by the CTV and OARs with the planned doses.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты