Right ventricular echocardiographic parameters and prediction of stroke volume in ischemic cardiogenic shock: A retrospective study.

Lashin Hazem, Olusanya Olusegun, Smith Andrew, Bhattacharyya Sanjeev

СтатьяПеревод в очереди

Аннотация

PURPOSE: This study investigated which commonly used right ventricular (RV) echocardiographic parameter correlates best with stroke volume (SV) estimated by Doppler echocardiography in ischemic cardiogenic shock (CS).

MATERIALS AND

METHODS

We retrospectively reviewed the records of 100 patients admitted to the ICU over 34 months with CS. Tricuspid annular plane systolic excursion (TAPSE), Tricuspid annulus systolic velocity (RV S'), Tricuspid regurgitation maximum velocity (TR Vmax), and RV outflow tract velocity time integral (RVOT VTI) were correlated to SV.

RESULTS

Mean age was 62.6 ± 12.7 years and 78% were male. The mean SV, TAPSE, RV S', TR Vmax, and RVOT VTI were 47 ± 16 ml, 16 ± 5 mm, 11 ± 4 mm/s, 1.97 ± 0.73 m/s, and 12.7 ± 5 cm, respectively. RVOT VTI correlated best to SV (r = 0.39 p = 0.01) compared to TAPSE, RV S', and TR Vmax (r = 0.26 p = 0.01, r = 0.15 p = 0.21, r = 0.03 p = 0.78). RVOT VTI independently predicted SV. Univariate analysis demonstrated that only RVOT VTI predicted SV (OD = 1.18 p = 0.04) and had the best area under the curve (0.70, p = 0.03).

CONCLUSION

RVOT VTI correlated better (albeit weakly) to and best predicted SV compared to TAPSE, RV S', and TR Vmax in patients admitted to intensive care with CS. This study suggests that RVOT VTI has the potential as a therapeutic target to optimize SV in CS.

Для цитирования: Lashin Hazem, Olusanya Olusegun, Smith Andrew, Bhattacharyya Sanjeev. Right ventricular echocardiographic parameters and prediction of stroke volume in ischemic cardiogenic shock: A retrospective study.. Journal of critical care. 2022. DOI: 10.1016/j.jcrc.2022.154219.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.