UNLABELLED: Polyetheretherketone (PEEK) polymer is a widely accepted implantable biomaterial in the biomedical field. However, PEEK has a low elastic modulus (E-modulus) as well as a bio-inert nature which is not conductive to rapid bone cell attachment, hence, producing delayed or weak bone-implant integration. Multiwalled carbon nanotubes (MWCNTs) represent one of the strongest known materials that could be added to a polymer to improve its mechanical properties. Bioactive glasses (BGs) can form hydroxyapatite deposits on their surfaces and form a tight bond with the bone, thus, their incorporation into the PEEK matrix may improve its bioactivity.

METHODS

Eight groups were formulated according to the type and percentage of modification of PEEK by MWCNTs and BGs. Group 1: Pure PEEK (P), Group 2: P + 3% MWCNTs (PC3), Group 3: P + 5% MWCNTs (PC5), Group 4: P + 5% BGs (PG5), Group 5: P + 10% BGs (PG10), Group 6: P + 3% MWCNTs + 5% BGs (PC3G5), Group 7: P + 3% MWCNTs + 10% BGs (PC3G10), and Group 8: P + 5% MWCNTs + 5% BGs (PC5G5). Characterization of the vacuum-pressed PEEK and PEEK composite specimens was done using FE-SEM, EDS, FT-IR and TF-XRD. Three-point load test was done to obtain the flexural strength (F.S) and the E-modulus of the specimens. Wettability was determined by measuring the contact angle with distilled water. In-vitro bioactivity was determined after immersion of specimens in simulated body fluid (SBF). Moreover, the effect of the specimens on osteoblastic cell viability was evaluated.

RESULTS

Three-point load test results have shown an improvement in both F.S. and E-modulus for groups PC5, PC3G5 and PC5G5. The lowest contact angle was obtained for group PC5G5 followed by the PC3G10 group. All specimens containing BGs showed the formation of hydroxyapatite-like deposits after their immersion in SBF, as well as an improvement in osteoblastic cell viability compared to PEEK.

CONCLUSION

PC3G10, PC3G5 and PG10, groups are promising for the fabrication of patient-specific implants that can be used in low-stress-bearing areas.

Для цитирования: Khallaf Reem Magdy, Emam Ahmed N, Mostafa Amany A, Nassif Mohamed Salah, Hussein Tarek Salah. Strength and bioactivity of PEEK composites containing multiwalled carbon nanotubes and bioactive glass.. Journal of the mechanical behavior of biomedical materials. 2023. DOI: 10.1016/j.jmbbm.2023.105964.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.