m+Medelevator.RU
← Поиск публикаций
Journal of chromatography. A · 2025

Overcoming analytical challenges of Other Test Method 50: Analysis of volatile fluorinated compounds in passivated canisters from stationary source emissions.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Wallace M Ariel Geer, Jackson Stephen R, Preston William T, Miles Laura, Calder Hannah, Davies Stephen, Cumbes Morgane

Аннотация

The production and emission of per- and polyfluoroalkyl substances (PFAS) has become a cause of concern due to their environmental persistence, accumulation, and potential health impacts. There are few methods for measuring air emissions of PFAS from fluorochemical manufacturing facilities and products of incomplete combustion or destruction (PICs/PIDs) that may be formed during incineration of PFAS-containing materials. The U.S. Environmental Protection Agency (EPA) developed Other Test Method (OTM)-50, a canister sampling and thermal desorption-gas chromatography/mass spectrometry (TD-GC/MS) analysis method for measuring volatile fluorinated compounds (VFCs) from stationary source emissions. Here, we describe the experiments that were conducted to develop the optimized analytical methods for samples that may contain high humidity and carbon dioxide (CO2) levels. A prototype preconcentrator with a focusing trap capable of reaching -100 °C was used to improve retention of tetrafluoromethane (CF4), but the lower temperature also trapped more CO2, which caused signal suppression of CF4 as well as hexafluoroethane, chlorodifluoromethane, tetrafluoroethene, and trifluoromethane. Therefore, the optimized method utilized a low trap temperature of -30 °C to avoid trapping high levels of CO2 that may be present in stationary source samples. We found that increasing the dry purge time to nine minutes during preconcentration eliminated enough CO2 to recover target compounds within ±30 % of the standard value, as required by OTM-50. The method was used to analyze samples collected in the absence and presence of high CO2 levels to demonstrate the precision of the method even under challenging conditions.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты