MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1540-8183.2009.00507.x

Медицинская библиотека · Journal of interventional cardiology · 2009

Impact of occluder device type on success of percutaneous closure of atrial septal defects--a medium-term follow-up study.

Becker Michael, Frings Dorothee, Schröder Jörg, Ocklenburg Christina, Mühler Eberhard, Hoffmann Rainer, Franke Andreas, Lepper Wolfgang

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To identify differences between various occluder types regarding thromboembolic event rates and existence of residual shunts during medium-term follow-up.

METHODS

Three hundred nine consecutive patients with presumed paradoxical embolism and scheduled for percutaneous closure of patent foramen ovale or atrial septal defect between 1997 and 2006 were considered for this study. Device implantation failed in seven patients (nonstable device position), so 302 patients (46 +/- 12 years, 190 males) formed the study group using Amplatzer (n = 208), Starflex (n = 61), and Cardiastar (n = 33) occluders. Follow-up transesophageal echocardiography was performed 1, 3, and 6 months after implantation.

RESULTS

Periinterventional complications occurred in two patients (cardiac arrhythmias). There were more residual shunts in the Starflex and Cardiastar group than in the Amplatzer group at 6-month follow-up (8/61 vs. 7/33 vs. 8/208, P = 0.0005). Performing logistic regression, the type of occluder device was a significant risk factor for the presence of residual shunt 6 months after implantation (P = 0.0033; Cardiastar vs. Amplatzer OR 6.346, 95% CI 1.998 - 20.156; Starflex vs. Amplatzer OR 4.369, 95% CI 1.444 - 13.222). During mean follow-up of 31 +/- 8 months 16 recurrent thromboembolic events occurred; the annual recurrence was 2.1% for combined end-point stroke, TIA, and peripheral embolism (Amplatzer: 1.3%, Starflex: 3.9%, and Cardiastar: 3.6%, P = 0.0467). The presence of an atrial septal aneurysm was the only significant risk factor (P = 0.0168, OR 3.664, 95% CI 1.263 - 10.630) for the occurrence of thromboembolic events.

CONCLUSIONS

Percutaneous closure of patent foramen ovale or atrial septal defect is a safe procedure with little incidence of peri- and postprocedural complications. There is a significant difference between the Amplatzer, Cardiastar, and Starflex occluders in regard to complete closure of the defects and annual recurrence of thromboembolic events.

Для цитирования: Becker Michael, Frings Dorothee, Schröder Jörg, Ocklenburg Christina, Mühler Eberhard, Hoffmann Rainer, Franke Andreas, Lepper Wolfgang. Impact of occluder device type on success of percutaneous closure of atrial septal defects--a medium-term follow-up study.. Journal of interventional cardiology. 2009. DOI: 10.1111/j.1540-8183.2009.00507.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.