MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/00007691-199402000-00003

Медицинская библиотека · Therapeutic drug monitoring · 1994

Radioimmunoassay for 7-hydroxy metabolite of fluphenazine and its application to plasma level monitoring in schizophrenic patients treated long term with oral and depot fluphenazine.

Aravagiri M, Marder S R, Van Putten T, Hawes E M, McKay G, Midha K K

СтатьяПоддержка исследования: вне правительства СШАПоддержка правительства СШАПоддержка службы здравоохранения СШАПеревод в очереди

Аннотация

Immunization of New Zealand white rabbits with a bovine serum albumin conjugate of 7-hydroxy-N-carboxyethyl-N-deshydroxyethylfluphenazine produced highly specific antisera for 7-hydroxyfluphenazine (7-OHFLU). A radioimmunoassay (RIA) was developed using antisera from one of the rabbits that enabled for the first time the determination of plasma levels of 7-OHFLU, an active metabolite of fluphenazine (FLU), in patients treated with oral FLU dihydrochloride or i.m. FLU decanoate. The assay method provided sufficient sensitivity to determine accurately 20 pg of 7-OHFLU in 200 microliters (0.1 ng/ml) of plasma with a coefficient of variation of < 10%. The antiserum used in the RIA for 7-OHFLU demonstrated negligible cross-reactivity with FLU and its metabolites such as FLU sulfoxide, N-deshydroxyethylFLU, FLU N4'-oxide, N-deshydroxyethyl-7-OHFLU, and 7-O-glucuronide of FLU and also with other antipsychotic agents and commonly coadministered drugs. The 7-OHFLU was present in measurable amounts in all plasma samples obtained at 4-week intervals from patients receiving a daily oral dose of 5 (n = 10), 10 (n = 13), or 20 (n = 14) mg of FLU dihydrochloride. Large interindividual variations in the plasma level of FLU and 7-OHFLU were noted and the mean plasma levels ratios of 7-OHFLU/FLU at these doses were 2.07 +/- 1.08, 2.07 +/- 1.13, and 2.02 +/- 0.82, respectively.(ABSTRACT TRUNCATED AT 250 WORDS)

Для цитирования: Aravagiri M, Marder S R, Van Putten T, Hawes E M, McKay G, Midha K K. Radioimmunoassay for 7-hydroxy metabolite of fluphenazine and its application to plasma level monitoring in schizophrenic patients treated long term with oral and depot fluphenazine.. Therapeutic drug monitoring. 1994. DOI: 10.1097/00007691-199402000-00003.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.