Аннотация

RATIONAL AND

OBJECTIVES

To investigate the effect of the Joint Photographic Experts Group (JPEG2000) 30:1 and 60:1 lossy compression on the detection of cranial vault fractures when compared to JPEG2000 lossless compression.

MATERIALS AND

METHODS

Fifty cranial computed tomography (CT) images were processed with three different level of JPEG2000 compression (lossless, 30:1 lossy, and 60:1 lossy) creating three sets of images. These were presented to five musculoskeletal specialists and five neuroradiologists. Each reader read at two of the three compression levels. Twenty-two cases contained a single fracture; the remaining 28 cases contained no fractures. Observers were asked to identify the presence or absence of a fracture, to locate its site, and rate their degree of confidence. Receiver operating characteristic (ROC), jackknife free-response receiver operating characteristic (JAFROC) and the Dorfman-Berbaum-Metz multiple reader multiple case (DBM-MRMC) analyses were used to explore differences between the lossless and lossy compressed images.

RESULTS

JPEG2000 lossless and 30:1 lossy compression demonstrated no significant difference in their performance with JAFROC and DBM-MRMC analysis (P < .416); however, JPEG2000 30:1 lossy compression demonstrated significantly better performance than 60:1 lossy compression (P < .016). A significant increase in misplaced confidence ratings was also seen with 60:1 (P < .037) over 30:1 lossy and lossless compression.

CONCLUSION

JPEG2000 60:1 compression degrades the detection of skull fractures significantly while increasing the confidence with which readers rate fractures compared with 30:1 lossy and lossless compression. JPEG2000 30:1 lossy compression does not significantly change performance when compared to JPEG2000 lossless for the detection of skull fractures on CT.

Для цитирования: McEntee Mark F, Nikolovski Ines, Bourne Roger, Pietrzyk Mariusz W, Evanoff Michael G, Brennan Patrick C, Tay Kevin L. The effect of JPEG2000 compression on detection of skull fractures.. Academic radiology. 2013. DOI: 10.1016/j.acra.2013.01.021.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.