MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/cid.12076

Медицинская библиотека · Clinical implant dentistry and related research · 2013

The socket-shield technique: first histological, clinical, and volumetrical observations after separation of the buccal tooth segment – a pilot study.

Bäumer Daniel, Zuhr Otto, Rebele Stephan, Schneider David, Schupbach Peter, Hürzeler Markus

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

The "socket-shield technique" has shown its potential in preserving buccal tissues. However, front teeth often have to be extracted due to vertical fractures in buccolingual direction. It has not yet been investigated if the socket-shield technique can only be used with intact roots or also works with a modified shield design referring to vertical fracture lines.

PURPOSE: The aim of this study was to assess histologically, clinically, and volumetrically the effect of separating the remaining buccal root segment in two pieces before immediate implant placement.

MATERIAL AND

METHODS

Three beagle dogs were selected in the study. The third and fourth premolars on both sides of the upper jaw were hemisected and the clinical crown of the distal root was removed. Then, the implant bed preparation was performed into the distal root so that a buccal segment of healthy tooth structure remained. This segment was then separated in a vertical direction into two pieces and implants placed lingual to it. After 4 months of healing, the specimens were processed for histological diagnosis. In a clinical case, the same technique was applied and impressions taken for volumetric evaluation by digital superimposition.

RESULTS

The tooth segments showed healthy periodontal ligament on the buccal side. New bone was visible between implant surface and shield as well as inside the vertical drill line. No osteoclastic remodeling of the coronal part of the buccal plate was observed. The clinical volumetric analysis showed a mean loss of 0.88 mm in labial direction with a maximum of 1.67 mm and a minimum of 0.15 mm.

CONCLUSION

The applied modification seems not to interfere with implant osseointegration and may still preserve the buccal plate. It may offer a feasible treatment option for vertically fractured teeth.

Для цитирования: Bäumer Daniel, Zuhr Otto, Rebele Stephan, Schneider David, Schupbach Peter, Hürzeler Markus. The socket-shield technique: first histological, clinical, and volumetrical observations after separation of the buccal tooth segment – a pilot study.. Clinical implant dentistry and related research. 2013. DOI: 10.1111/cid.12076.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.