MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.vaa.2016.08.006

Медицинская библиотека · Veterinary anaesthesia and analgesia · 2017

The effect of anesthetic drug choice on accuracy of high-definition oscillometry in laterally recumbent horses.

Duke-Novakovski Tanya, Ambros Barbara, Feng Cindy, Carr Anthony P

Клиническое исследованиеСтатьяПеревод в очереди

Аннотация

OBJECTIVE

To determine the accuracy of high-definition oscillometry (HDO) for arterial pressure measurement during injectable or inhalation anesthesia in horses.

STUDY

DESIGN

Prospective, clinical study.

ANIMALS: Twenty-four horses anesthetized for procedures requiring lateral recumbency.

METHODS

Horses were premedicated with xylazine, and anesthesia induced with diazepam-ketamine. Anesthesia was maintained with xylazine-ketamine-guaifenesin combination [TripleDrip (TD; n = 12) or isoflurane (ISO; n = 12)]. HDO was used to obtain systolic (SAP), mean (MAP) and diastolic (DAP) arterial pressures, and heart rate (HR) using an 8-cm-wide cuff around the proximal tail. Invasive blood pressure (IBP), SAP, MAP, DAP and HR were recorded during HDO cycling. Bland-Altman analysis for repeated measures was used to compare HDO and IBP for all measurements. The generalized additive model was used to determine if means in the differences between HDO and IBP were similar between anesthetic protocols for all measurements.

RESULTS

There were >110 paired samples for each variable. There was no effect of anesthetic choice on HDO performance, but more variability was present in TD compared with ISO. Skewed data required log-transformation for statistical comparison. Using raw data and standard Bland-Altman analysis, HDO overestimated SAP (TD, 3.8 ± 28.3 mmHg; ISO, 3.5 ± 13.6 mmHg), MAP (TD, 4.0 ± 23.3 mmHg; ISO, 6.3 ± 10.0 mmHg) and DAP (TD, 4.0 ± 21.2 mmHg; ISO, 7.8 ± 13.6 mmHg). In TD, 26-40% HDO measurements were within 10 mmHg of IBP, compared with 60-74% in ISO. Differences between HDO and IBP for all measurements were similar between anesthetic protocols. The numerical difference between IBP and HDO measurements for SAP, MAP and DAP significantly decreased as cuff width:tail girth ratio increased toward 40%.

CONCLUSION AND CLINICAL RELEVANCE: More variability in HDO occurred during TD. The cuff width:tail girth ratio is important for accuracy of HDO.

Для цитирования: Duke-Novakovski Tanya, Ambros Barbara, Feng Cindy, Carr Anthony P. The effect of anesthetic drug choice on accuracy of high-definition oscillometry in laterally recumbent horses.. Veterinary anaesthesia and analgesia. 2017. DOI: 10.1016/j.vaa.2016.08.006.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.