MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jmoldx.2019.11.002

Медицинская библиотека · The Journal of molecular diagnostics : JMD · 2019

Validation of Fragile X Screening in the Newborn Population Using a Fit-for-Purpose FMR1 PCR Assay System.

Lee Stacey, Taylor Jennifer L, Redmond Charles, Hadd Andrew G, Kemppainen Jon A, Haynes Brian C, Shone Scott, Bailey Donald B, Latham Gary J

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Newborn screening is designed for presymptomatic identification of serious conditions with effective early interventions. Clinical laboratories must perform prospective pilot studies to ensure that the analytical performance and workflow for a given screening test are appropriate. We assessed the potential to screen newborns for fragile X syndrome, a monogenic neurodevelopmental disorder, by establishing a customized, high-throughput PCR and analysis software system designed to detect fragile X mental retardation 1 gene repeat expansions from dried blood spots (DBSs). Assay precision, accuracy, sensitivity, and specificity were characterized across the categorical range of repeat expansions. The assay consistently resolved genotypes within three CGG repeats of reference values up to at least 137 repeats and within six repeats for larger expansions up to 200 repeats. Accuracy testing results were concordant with reference results. Full and premutation alleles were detected from subnanogram DNA inputs eluted from DBSs and from mixtures with down to 1% relative abundance of the respective expansion. Analysis of 963 deidentified newborn DBS samples identified 957 normal and 6 premutation specimens, consistent with previously published prevalence estimates. These studies demonstrate that the assay system can support high-throughput newborn screening programs.

Для цитирования: Lee Stacey, Taylor Jennifer L, Redmond Charles, Hadd Andrew G, Kemppainen Jon A, Haynes Brian C, Shone Scott, Bailey Donald B, Latham Gary J. Validation of Fragile X Screening in the Newborn Population Using a Fit-for-Purpose FMR1 PCR Assay System.. The Journal of molecular diagnostics : JMD. 2019. DOI: 10.1016/j.jmoldx.2019.11.002.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.