The impact of cardiac resynchronization therapy on diastolic parameters and mitral regurgitation: echocardiographic analysis of ultrasound-based left ventricular endocardial pacing system.

Wilson Ryan, Sharma Dinesh, James Simon, Eguchi Shunsuke, Orihara Yoshiyuki, Navas Viviana, Bhardwaj Rahul, Pfeiffer Michael, Kubo Spencer H

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The WiSE-CRT system offers an innovative approach to biventricular pacing in individuals who previously were considered too high risk or had failed traditional transvenous CRT therapy. The impact on LV volumes and systolic function have previously been published. This study evaluates the impact of the WiSE CRT system on diastolic filling parameters and mitral regurgitation.

METHODS

Retrospective cohort study of patients in SOLVE-CRT with device implantation, activated CRT therapy, and a 6-month follow-up TTE. Baseline and 6-month parameters of diastolic function and mitral regurgitation were evaluation. Most patients had sufficient data for analysis. A sub-group analysis examined results in ischemic and non-ischemic cardiomyopathies.

RESULTS

Individual parameters of diastolic function and mitral regurgitation trended towards improvement at 6-months. Summative classification of diastolic function and mitral regurgitation both showed statistically significant improvement at 6-months follow-up (p < 0.01).

CONCLUSION

In addition to the established improvement in LV volumes and LV EF, patients with the WiSE-CRT biventricular pacing system demonstrate improvement in aggregate assessment of diastolic function and mitral regurgitation at 6-months.

Для цитирования: Wilson Ryan, Sharma Dinesh, James Simon, Eguchi Shunsuke, Orihara Yoshiyuki, Navas Viviana, Bhardwaj Rahul, Pfeiffer Michael, Kubo Spencer H. The impact of cardiac resynchronization therapy on diastolic parameters and mitral regurgitation: echocardiographic analysis of ultrasound-based left ventricular endocardial pacing system.. Frontiers in cardiovascular medicine. 2026. DOI: 10.3389/fcvm.2026.1768362.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.