[Progressive cardiac tamponade and right ventricular free wall perforation as complications after dual-chamber pacemaker implantation - a case report].

Buszkiewicz Karol, Greberski Krzysztof, Łuczak Maciej, Angerer Dariusz, Poprawka Tomasz, Bugajski Paweł

Клинический случайСтатьяПеревод в очереди

Аннотация

UNLABELLED: In recent years the number of complications related to implantation of cardiac stimulating systems is increasing. Life-threatening myocardial perforation leading to cardiac tamponade is one of the rarest complications. In that case it is necessary to take the immediate lifesaving procedures.

A CASE REPORT: 61-year-old woman ended up in the cardiac surgery department with progressive cardiac tamponade and cardiogenic shock symptoms. Three weeks earlier due to the tachycardia-bradycardia syndrome with second-degree atrioventricular block diagnosis, the cardiac stimulating system was implanted into the heart at the cardiology department. Two days after the discharge from hospital the patient appeared in the emergency department with non-specific chest symptoms, which disappeared after analgesic drugs. After another two weeks the patient returned to the emergency department in general poor condition. Echocardiographic examination showed fluid in both pleural cavities, a dense layer around heart and fluid out wards from the layer in the pericardial space. Furthermore, CT scan showed unobvious shape crossing the heart muscle. Firstly, the patient was admitted to the cardiology department and next transferred to the cardio surgery where on account of deteriorating condition was made a decision urgent sternotomy and revision pericardial sac. Intraoperatively were found perforation of right ventricular free wall caused by stimulation electrode and hole communicating pericardial space with left pleural cavity. The operation went well, without any complications. The patient was discharged from hospital 12 days after surgery.

CONCLUSIONS

In the case of suspected complications related to the implantation of electrostimulation equipment, it is necessary to perform appropriate diagnostics and implement urgent procedures, including surgery.

Для цитирования: Buszkiewicz Karol, Greberski Krzysztof, Łuczak Maciej, Angerer Dariusz, Poprawka Tomasz, Bugajski Paweł. [Progressive cardiac tamponade and right ventricular free wall perforation as complications after dual-chamber pacemaker implantation - a case report].. Polski merkuriusz lekarski : organ Polskiego Towarzystwa Lekarskiego. 2021.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.