[Cervicofacial cancerology: complications of implantable systems of venous access. Prospective study].
Аннотация
OBJECTIVE
Implantable systems for venous access are widely used in cervicofacial cancer. We prospectively evaluated complications related to this type of venous access in our cancer patients.
METHODS
From September 1991 to September 1993, an implantable system for venous access was installed in 164 patients with epidermoid carcinoma of the upper respiratory and digestive tracts. The systems were implanted in the subclavian vein by 20 different operators (mean number of implants per operator = 8.2). All catheters were tunnelized. Chemotherapy was a combination of 5 fluorouracil and cisplatinum.
RESULTS
Immediate complications included impossible implantation (n = 12, 7.3%), pneumothorax (n = 5), false passage (n = 4), haematoma (n = 3), arterial puncture (n = 2) and abscess of the thoracic wall (n = 1). During use, complications included extravasation (n = 4), catheter thrombosis (n = 2), venous thrombosis (n = 2) and infection at the site of implantation, desinsertion of the catheter from the chamber, haematoma at the site of implantation and septicaemia (n = 1 each). The rate of complications was related to implantation (17% of the implantations) or to use (8%).
CONCLUSIONS
The rate of complications due to implantable venous access systems is relatively low, suggesting that these systems are acceptable for ambulatory chemotherapy.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.