MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.chroma.2004.05.035

Медицинская библиотека · Journal of chromatography. A · 2004

Packed column supercritical fluid chromatography of a peroxysome proliferator-activating receptor agonist drug. Achiral and chiral purity of substance, formulation assay and its enantiomeric purity.

Gyllenhaal Olle

СтатьяПеревод в очереди

Аннотация

This paper describes packed column supercritical fluid chromatography (SFC) for the analysis of a peroxysome proliferator-activating gamma-receptor agonist that is a carboxylic acid. Evaluation of conditions for the separation of this candidate drug and related compounds in bulk substance is described. A Chiralcel OD column was used for this purpose due to its high selective retention of related substances and relative inertness, though the enantioselectivity was negligible, with methanol as polar modifier. A high enantioselectivity was obtained on Chiralpak AD and it was possible to determine the enantiomeric purity within 10 min on a 5 cm short column. Both the achiral and the chiral systems were run without acid additive in the mobile phase and the level of detection of impurities by area was about 0.1%. For the analysis of samples dissolved in water, without any isolation step, 2-propanol was used as modifier. Due to the column surface activity, evidently generated by injected water, citric acid 1 mM was included as additive in the 2-propanol in order to maintain symmetric and undistorted peak shape. The detection limit for the assay was 21 microg mL(-1) (50 nmol mL(-1)) for 5 microL injected (R.S.D. 6.4%, n = 8). A 5 cm short Chiralcel OD column was used. Determination of enantiomeric purity of the drug in aqueous samples required increased sensitivity. The sample was acidified and extracted into a small volume of 1-pentanol, out of which 25 microl was analyzed by SFC. The minor enantiomer at the 3% (w/w) level added could be confirmed. Its ratio remained constant during the procedure as measured relative to a reference solution in organic media.

Для цитирования: Gyllenhaal Olle. Packed column supercritical fluid chromatography of a peroxysome proliferator-activating receptor agonist drug. Achiral and chiral purity of substance, formulation assay and its enantiomeric purity.. Journal of chromatography. A. 2004. DOI: 10.1016/j.chroma.2004.05.035.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.