DOI 10.7150/thno.54959

Медицинская библиотека · Theranostics · 2021

Injectable conductive hydrogel can reduce pacing threshold and enhance efficacy of cardiac pacemaker.

An Zhao, Wu Jun, Li Shu-Hong, Chen Shanglin, Lu Fang-Lin, Xu Zhi-Yun, Sung Hsing-Wen, Li Ren-Ke

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Background

Pacemaker implantation is currently used in patients with symptomatic bradycardia. Since a pacemaker is a lifetime therapeutic device, its energy consumption contributes to battery exhaustion, along with its voltage stimulation resulting in local fibrosis and greater resistance, which are all detrimental to patients. The possible resolution for those clinical issues is an injection of a conductive hydrogel, poly-3-amino-4-methoxybenzoic acid-gelatin (PAMB-G), to reduce the myocardial threshold voltage for pacemaker stimulation.

Methods

PAMB-G is synthesized by covalently linking PAMB to gelatin, and its conductivity is measured using two-point resistivity. Rat hearts are injected with gelatin or PAMB-G, and pacing threshold is evaluated using electrocardiogram and cardiac optical mapping.

Results

PAMB-G conductivity is 13 times greater than in gelatin. The ex vivo model shows that PAMB-G significantly enhances cardiac tissue stimulation. Injection of PAMB-G into the stimulating electrode location at the myocardium has a 4 times greater reduction of pacing threshold voltage, compared with electrode-only or gelatin-injected tissues. Multi-electrode array mapping reveals that the cardiac conduction velocity of PAMB-G group is significantly faster than the non- or gelatin-injection groups. PAMB-G also reduces pacing threshold voltage in an adenosine-induced atrial-ventricular block rat model.

Conclusion

PAMB-G hydrogel reduces cardiac pacing threshold voltage, which is able to enhance pacemaker efficacy.

Для цитирования: An Zhao, Wu Jun, Li Shu-Hong, Chen Shanglin, Lu Fang-Lin, Xu Zhi-Yun, Sung Hsing-Wen, Li Ren-Ke. Injectable conductive hydrogel can reduce pacing threshold and enhance efficacy of cardiac pacemaker.. Theranostics. 2021. DOI: 10.7150/thno.54959.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.