MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1515/cclm-2025-0128

Медицинская библиотека · Clinical chemistry and laboratory medicine · 2025

The accuracy of presepsin in diagnosing neonatal late-onset sepsis in critically ill neonates: a prospective study.

Auriti Cinzia, De Rose Domenico Umberto, Maddaloni Chiara, Ravà Lucilla, Martini Ludovica, Di Tommaso Eleonora, Bernaschi Paola, Paionni Emanuel, Porzio Ottavia, Piersigilli Fiammetta, Iannetta Marco, Dotta Andrea, Ronchetti Maria Paola

СтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVES

The diagnostic accuracy of presepsin (P-SEP) in the newborn is still under evaluation.

METHODS

In a multicenter study, we studied the accuracy of P-SEP as a diagnostic marker of late-onset sepsis (LOS) in critical newborns with underlying disorders, to define the most accurate cut-off to distinguish infected from uninfected patients.

RESULTS

Sixty-nine/351 newborns without infections at admission developed LOS. The median P-SEP value at T0 (admission) was 518.0 ng/L (IQR 313.0-789.0), without significant differences related to underlying diseases (p=0.52). In neonates who developed LOS, P-SEP increased at the onset of infection (T1) (median: 816.0 ng/L) and after 24-48 h (median: 901.0 ng/L) compared with their value at admission (median: 560.0 ng/L) (p<0.01 and p=0.03, respectively). The area under the ROC curve at T1 was 0.71 (95 % CI 0.65-0.78) when all cases of sepsis were included in the analysis and increased to 0.74 (95 % CI 0.66-0.81) considering only confirmed sepsis. Approximately two-thirds of patients were correctly classified, setting the cut-off at 713 ng/L, with a negative predictive value of 89.0 %.

CONCLUSIONS

At a cut-off of 713 ng/L, P-SEP has good accuracy in diagnosing LOS in critically ill newborns. In uninfected newborns, the median value of P-SEP is not influenced by any underlying pathology.

Для цитирования: Auriti Cinzia, De Rose Domenico Umberto, Maddaloni Chiara, Ravà Lucilla, Martini Ludovica, Di Tommaso Eleonora, Bernaschi Paola, Paionni Emanuel, Porzio Ottavia, Piersigilli Fiammetta, Iannetta Marco, Dotta Andrea, Ronchetti Maria Paola. The accuracy of presepsin in diagnosing neonatal late-onset sepsis in critically ill neonates: a prospective study.. Clinical chemistry and laboratory medicine. 2025. DOI: 10.1515/cclm-2025-0128.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.