MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1039/b819688e

Медицинская библиотека · Lab on a chip · 2009

Lab-on-a-chip for multiplexed biosensing of residual antibiotics in milk.

Suárez Guillaume, Jin Young-Hyun, Auerswald Janko, Berchtold Stefan, Knapp Helmut F, Diserens Jean-Marc, Leterrier Yves, Månson Jan-Anders E, Voirin Guy

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

A multiplexed immunoassay-based antibiotic sensing device integrated in a lab-on-a-chip format is described. The approach is multidisciplinary and involves the convergent development of a multi-antibiotic competitive immunoassay based on sensitive wavelength interrogated optical sensor (WIOS) technology and a polymer-based self-contained microfluidic cartridge. Immunoassay solutions are pressure-driven through external and concerted actuation of a single syringe pump and multiposition valve. Moreover, the use of a novel photosensitive material in a 'one step' fabrication process allowed the rapid fabrication of microfluidic components and interconnection port simultaneously. Pre-filled microfluidic cartridges were used as binary response rapid tests for the simultaneous detection of three antibiotic families - sulfonamides, fluoroquinolones and tetracyclines - in raw milk. For test interpretation, any signal lower than the threshold value obtained for the corresponding Maximum Residue Limit (MRL) concentration (100 microg L(-1)) was considered negative for a given antibiotic. The reliability of the multiplexed detection system was assessed by way of a validation test carried out on a series of six blind milk samples. A test accuracy of 95% was calculated from this experiment. The whole immunoassay procedure is fast (less than 10 minutes) and easy to handle (automated actuation).

Для цитирования: Suárez Guillaume, Jin Young-Hyun, Auerswald Janko, Berchtold Stefan, Knapp Helmut F, Diserens Jean-Marc, Leterrier Yves, Månson Jan-Anders E, Voirin Guy. Lab-on-a-chip for multiplexed biosensing of residual antibiotics in milk.. Lab on a chip. 2009. DOI: 10.1039/b819688e.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.