PURPOSE: Temporal subtraction images constructed from image registration can facilitate the visualization of pathologic changes. In this study, we propose a deformable image registration (DIR) framework for creating temporal subtraction images of chest radiographs.

METHODS

We developed a DIR methodology using two different image similarity metrics, varying flow (VF) and compressible flow (CF). The proposed registration method consists of block matching, filtering, and interpolation. Specifically, corresponding point pairs between reference and target images are initially determined by minimizing a nonlinear least squares formulation using grid-searching optimization. A two-step filtering process, including least median of squares filtering and backward matching filtering, is then applied to the estimated point matches in order to remove erroneous matches. Finally, moving least squares is used to generate a full displacement field from the filtered point pairs.

RESULTS

We applied the proposed DIR method to 10 pairs of clinical chest radiographs and compared it with the demons and B-spline algorithms using the five-point rating score method. The average quality scores were 2.7 and 3 for the demons and B-spline methods, but 3.5 and 4.1 for the VF and CF methods. In addition, subtraction images improved the visual perception of abnormalities in the lungs by using the proposed method.

CONCLUSION

The VF and CF models achieved a higher accuracy than the demons and the B-spline methods. Furthermore, the proposed methodology demonstrated the ability to create clinically acceptable temporal subtraction chest radiographs that enhance interval changes and can be used to detect abnormalities such as non-small cell lung cancer.

Для цитирования: Li Min, Castillo Edward, Luo Hong-Yan, Zheng Xiao-Lin, Castillo Richard, Meshkov Dmitriy, Guerrero Thomas. Deformable image registration for temporal subtraction of chest radiographs.. International journal of computer assisted radiology and surgery. 2014. DOI: 10.1007/s11548-013-0947-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.