MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/ccd.30485

Медицинская библиотека · Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2022

Risk factors for percutaneous left ventricular assist device explant complications.

Schott Jason P, Rusia Akash, Lynch Stephen, Tawney Adam, Mustafa Syed F, Balla Abdalla K, Hanson Ivan D

Многоцентровое исследованиеСтатьяПеревод в очереди

Аннотация

INTRODUCTION

Percutaneous left ventricular assist device (pLVAD) explant remains nonstandardized with potential complications of bleeding and thrombosis. Explant settings include percutaneous techniques in the catheterization laboratory (CL), manually at bedside (MB), and surgically in the operating room (OR).

OBJECTIVE

Identify high-risk features for explant-related complications, including indication for support, setting, and technique.

METHODS

Postexplant bleeding and thrombosis/limb ischemia were identified following pLVAD removals over 2 years at a multicenter healthcare system.

RESULTS

Of 156 patients, bleeding (n = 26 [17%]) and thrombosis (n = 9 [6%]) occurred more often in patients with the peripheral arterial disease (PAD), female gender, anemia, and cardiogenic shock. OR explants had a higher combined endpoint (4/8 [50%]) versus CL (23/133 [17%], p < 0.05) driven by transfusion. There was no difference between OR versus MB (5/15 [33%], p = 0.66) or CL versus MB (p = 0.62). In shock patients, there was no difference between CL (7/30 [23%]) versus MB (5/15 [33%], p = 0.5) and OR (4/7 [57%], p = 0.16); or MB versus OR (p = 0.38). Average length of stay was significantly lower in the CL group versus MB and OR (3.6 ± 33.2 vs. 18.4 ± 10.9 vs. 28.1 ± 15.8 days, p < 0.0001). Preclosure in shock patients (5/25 [20%] vs. 11/27 [41%], p = 0.1383) and crossover balloon occlusion technique (9/44 [16%] vs. 25/112 [22%]; p = 1) were not associated with higher combined endpoints versus control.

CONCLUSION

Risk factors for pLVAD explant complications include PAD, female gender, and cardiogenic shock. There was no difference in complication rates between explant settings among cardiogenic shock patients, but shorter length of stay when performed in the CL. There was no difference in complication rates when using the crossover balloon occlusion technique.

Для цитирования: Schott Jason P, Rusia Akash, Lynch Stephen, Tawney Adam, Mustafa Syed F, Balla Abdalla K, Hanson Ivan D. Risk factors for percutaneous left ventricular assist device explant complications.. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2022. DOI: 10.1002/ccd.30485.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.