MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/mrm.25035

Медицинская библиотека · Magnetic resonance in medicine · 2013

Effect of diffusion time on liver DWI: an experimental study of normal and fibrotic livers.

Zhou Iris Y, Gao Darwin S, Chow April M, Fan Shujuan, Cheung Matthew M, Ling Changchun, Liu Xiaobing, Cao Peng, Guo Hua, Man Kwan, Wu Ed X

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: To investigate whether diffusion time (Δ) affects the diffusion measurements in liver and their sensitivity in detecting fibrosis.

METHODS

Liver fibrosis was induced in Sprague-Dawley rats (n = 12) by carbon tetrachloride (CCl(4)) injections. Diffusion-weighted MRI was performed longitudinally during 8-week CCl(4) administration at 7 Tesla (T) using single-shot stimulated-echo EPI with five b-values (0 to 1000 s/mm(2)) and three Δs. Apparent diffusion coefficient (ADC) and true diffusion coefficient (D(true)) were calculated by using all five b-values and large b-values, respectively.

RESULTS

ADC and D(true) decreased with Δ for both normal and fibrotic liver at each time point. ADC and D(true) also generally decreased with the time after CCl(4) insult. The reductions in D(true) between 2-week and 4-week CCl(4) insult were larger than the ADC reductions at all Δs. At each time point, D(true) measured with long Δ (200 ms) detected the largest changes among the 3 Δs examined. Histology revealed gradual collagen deposition and presence of intracellular fat vacuoles after CCl(4) insult.

CONCLUSION

Our results demonstrated the Δ dependent diffusion measurements, indicating restricted diffusion in both normal and fibrotic liver. D(true) measured with long Δ acted as a more sensitive index of the pathological alterations in liver microstructure during fibrogenesis.

Для цитирования: Zhou Iris Y, Gao Darwin S, Chow April M, Fan Shujuan, Cheung Matthew M, Ling Changchun, Liu Xiaobing, Cao Peng, Guo Hua, Man Kwan, Wu Ed X. Effect of diffusion time on liver DWI: an experimental study of normal and fibrotic livers.. Magnetic resonance in medicine. 2013. DOI: 10.1002/mrm.25035.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.