MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcin.2009.06.016

Медицинская библиотека · JACC. Cardiovascular interventions · 2009

Expanding the eligibility for transcatheter aortic valve implantation the trans-subclavian retrograde approach using: the III generation CoreValve revalving system.

Fraccaro Chiara, Napodano Massimo, Tarantini Giuseppe, Gasparetto Valeria, Gerosa Gino, Bianco Roberto, Bonato Raffaele, Pittarello Demetrio, Isabella Giambattista, Iliceto Sabino, Ramondo Angelo

Клинический случайСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVES

Our aim was to assess the safety and feasibility of the retrograde trans-subclavian approach to transcatheter aortic valve implantation (TAVI) in selected high-risk patients with aortic stenosis (AS) and severe peripheral vasculopathy.

BACKGROUND

TAVI is an emerging therapeutic option to treat inoperable/high-risk patients affected by symptomatic AS. However, these patients are also often affected by severe iliac-femoral arteriopathy, rendering the transfemoral approach unemployable for percutaneous revalving procedure.

METHODS

From among those patients in our department between May 2007 and December 2008, who were refused surgical aortic valve replacement because of high surgical risk and were ineligible for transfemoral percutaneous aortic valve replacement, we scheduled 3 for TAVI by the subclavian approach. Procedures were performed by a combined team of cardiologists, cardiac surgeons, and anesthetists in the catheterization laboratory. The III generation CoreValve Revalving System (CoreValve Inc., Irvine, California) with an 18-F delivery system was introduced in all cases by the left subclavian artery.

RESULTS

Prosthetic valves were successfully implanted in all 3 cases, leading to a fall in transvalvular gradient without significant paravalvular regurgitation. No intraprocedural or periprocedural complications occurred. Two patients developed an atrioventricular block requiring the implantation of a permanent pacemaker. All patients were discharged in asymptomatic status, with good prosthesis performance. No adverse events occurred within the 3-month follow-up.

CONCLUSIONS

TAVI by subclavian retrograde approach seems safe and feasible in inoperable/high-risk patients with AS and peripheral vasculopathy, who are neither eligible for surgical valve replacement nor transfemoral percutaneous aortic valve implantation. Further studies are needed to evaluate the long-term efficacy of this new therapy.

Для цитирования: Fraccaro Chiara, Napodano Massimo, Tarantini Giuseppe, Gasparetto Valeria, Gerosa Gino, Bianco Roberto, Bonato Raffaele, Pittarello Demetrio, Isabella Giambattista, Iliceto Sabino, Ramondo Angelo. Expanding the eligibility for transcatheter aortic valve implantation the trans-subclavian retrograde approach using: the III generation CoreValve revalving system.. JACC. Cardiovascular interventions. 2009. DOI: 10.1016/j.jcin.2009.06.016.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.