Australasian journal on ageing · 2025
Pilot implementation of an electronic diagnostic support tool (AiD-DST) designed to identify the cause(s) of delirium.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Leong Elizabeth, Chang Stephane, Yearwood Kristi, Eeles Eamonn, Yerkovich Stephanie, Ling Carolina, Teodorczuk Andrew, Dissanayaka Nadeeka
Аннотация
OBJECTIVE(S): The identification of cause(s) of delirium remains a clinical challenge within medicine. Our group have previously successfully developed and tested the Aetiology in Delirium-Decision Support Tool (AiD-DST). The AiD-DST is designed to help medical professionals close the gap on the detection of cause(s) of delirium. Here, we report on use of AiD-DST in the real-world setting.
METHODS: A real-world implementation study of the AiD-DST within a general medical ward of a metropolitan hospital was conducted over a 10-week period. A mixed method evaluation was performed based upon the RE-AIM Framework that incorporates reach, effectiveness, adoption, implementation and maintenance of an intervention.
RESULTS: Reach: fifty-three out of 87 (61%) eligible doctors consented to participation in the study.
EFFECTIVENESS: A mean of 4.3 diagnoses were generated per patient with no difference in frequency when compared with historical control (z = 1.36; p = .17). Average usability score was 5.86 (SD = 1.15) on a 7-point scale, with 93% of respondents being satisfied with the AiD-DST. Free text feedback comprised themes of accessibility, ergonomics, diagnostic accuracy and applicability of AiD-DST to related conditions.
IMPLEMENTATION: Instrument completion rate was 98% (n = 49/50), with a median completion time of 90 s. Maintenance: Sixty-seven % of uses of AiD-DST occurred in the second half of the study (p = .3). Following the initiation period there was an increase in use (r = .79; p = 02).
CONCLUSION: Proof of principle was demonstrated for local implementation of a diagnostic support tool (AiD-DST).
METHODS: A real-world implementation study of the AiD-DST within a general medical ward of a metropolitan hospital was conducted over a 10-week period. A mixed method evaluation was performed based upon the RE-AIM Framework that incorporates reach, effectiveness, adoption, implementation and maintenance of an intervention.
RESULTS: Reach: fifty-three out of 87 (61%) eligible doctors consented to participation in the study.
EFFECTIVENESS: A mean of 4.3 diagnoses were generated per patient with no difference in frequency when compared with historical control (z = 1.36; p = .17). Average usability score was 5.86 (SD = 1.15) on a 7-point scale, with 93% of respondents being satisfied with the AiD-DST. Free text feedback comprised themes of accessibility, ergonomics, diagnostic accuracy and applicability of AiD-DST to related conditions.
IMPLEMENTATION: Instrument completion rate was 98% (n = 49/50), with a median completion time of 90 s. Maintenance: Sixty-seven % of uses of AiD-DST occurred in the second half of the study (p = .3). Following the initiation period there was an increase in use (r = .79; p = 02).
CONCLUSION: Proof of principle was demonstrated for local implementation of a diagnostic support tool (AiD-DST).