Медицинская библиотека · Archivos de cardiologia de Mexico · 2025

Efecto de la ventilación mecánica en la variabilidad de la oximetría de pulso en el posoperatorio de cirugía cardiaca.

Santos-Martínez Luis E, Gámez-Escamilla Marissa, López-Nuño Julio E, Ordóñez-Reyna Adriana, Reséndiz-Herrera Raúl, Quevedo-Paredes Javier, Cruz-Sánchez Jacobo J, González-Ruiz Francisco J

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To describe whether mechanical ventilation participates in the variability of pulse oximetry in subjects in critical conditions.

METHODS

Postoperative cardiac surgery subjects with and without mechanical ventilation were analized; their demographic variables, heart rate and arterial blood gases were defined. Variability was obtained from the comparison of arterial saturation (SaO2) and partial oxygen saturation (SpO2). They were obtained from blood gases, a pocket-sized Nonin pulse oximeter, and a Phillips monitor. It was analyzed with the Bland-Altman procedure.

RESULTS

260 subjects and 780 pairs of comparisons were studied. The mean difference (bias) with and without mechanical ventilation: SaO2 monitor 0.0 (6.3, -6.3) vs. 0.1 (6.3, -6.2); SaO2 Nonin 1.2 (7.7, -5.3) vs. 1.4 (7.2, -4.4); SpO2 Nonin - SpO2 monitor 1.2 (6.6, -4.2) vs. 1.3 (5.8, -3.2). The heart rate: auscultation monitor -0.5 (3.6, -4.5) vs. -0.1 (3, -3.3); auscultation Nonin -1.1 (7.4, -9.7) vs. -0.8 (4.2, -5.7); monitor - Nonin -0.6 (3, -4.3) vs. -0.6 (3, -4.3).

CONCLUSIONS

Mechanical ventilation does not increase heart rate or partial oxygen saturation variability in critically ill subject's post-cardiac surgery.

Для цитирования: Santos-Martínez Luis E, Gámez-Escamilla Marissa, López-Nuño Julio E, Ordóñez-Reyna Adriana, Reséndiz-Herrera Raúl, Quevedo-Paredes Javier, Cruz-Sánchez Jacobo J, González-Ruiz Francisco J. Efecto de la ventilación mecánica en la variabilidad de la oximetría de pulso en el posoperatorio de cirugía cardiaca.. Archivos de cardiologia de Mexico. 2025. DOI: 10.24875/acm.24000213.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.