Медицинская библиотека · JSLS : Journal of the Society of Laparoendoscopic Surgeons · 2006

A spiral tack as a lead point for volvulus.

Withers Laura, Rogers Ann

Клинический случайСтатьяОбзорПеревод в очереди

Аннотация

BACKGROUND AND

OBJECTIVES

We present a case of small bowel volvulus around an endotack applied during total extraperitoneal laparoscopic hernia repair (TEP). This complication prompts reconsideration of the role of tacks during extraperitoneal laparoscopic hernia repairs.

METHODS

We undertook a chart review and provide a case presentation with review of the literature.

RESULT: A 66-year-old male with bilateral inguinal hernias underwent elective, bilateral, total extraperitoneal laparoscopic hernia repair. During dissection, a small peritoneal tear occurred. The tear was closed with a spiral tack. On postoperative day 22, the patient developed an acute abdomen. Exploratory laparotomy revealed a volvulus rotated around an adhesion to the spiral tack.

DISCUSSION: Volvulus can cause vascular compromise leading to bowel ischemia and necrosis. A tack resulting in adhesion and volvulus is an unusual, but serious, complication. Repair of a peritoneal tear during preperitoneal hernia repair is advocated to improve visualization obstructed by a pneumoperitonuem and decrease adhesions to the abdominal wall.

CONCLUSION

The use of blunt Endoloops or crimps may prove safer than tacks for repairing the peritoneum and placement in proximity to delicate or thin tissues. Additionally, careful placement of foreign bodies to ensure their stability and to minimize protrusion may decrease the risk of erosion of the hardware.

Для цитирования: Withers Laura, Rogers Ann. A spiral tack as a lead point for volvulus.. JSLS : Journal of the Society of Laparoendoscopic Surgeons. 2006.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.