MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s12529-011-9180-7

Медицинская библиотека · International journal of behavioral medicine · 2012

Agreement in regard to total sleep time during a nap obtained via a sleep polygraph and accelerometer: a comparison of different sensitivity thresholds of the accelerometer.

Kawada Tomoyuki, Suzuki Hiroko, Shimizu Takako, Katsumata Masao

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Appropriate sensitivity threshold of accelerometer to measure total sleep time during nap is not established.

PURPOSE: Actigraphy-derived total sleep times during naps were calculated using three different sensitivity threshold values and compared with polysomnography.

METHOD: The mean age of the 60 subjects (53 men and 7 women) was 22.8, ranging from 22 to 27 years. Determination of the sleep stage by the polygraph and the sleep/wake judgment by the accelerometer obeyed the sleep/wake judgment, and the accelerometer was monitored under different sensitivity threshold settings. The study was carried out during one afternoon with a 3-h nap opportunity. Kappa statistics, correlations, and several indices of accuracy were compared using statistical methods.

RESULTS

The mean total sleep times during a nap set for 180 min were 160.4, 151.8, and 140.5 min, respectively, as judged under the low-sensitive, middle-sensitive, high-sensitive settings of an accelerometer worn on the non-dominant wrist. The corresponding mean total sleep time as calculated using a sleep polygraph was 133.0 min. Sleep/wake judgment by three levels of threshold values for the accelerometer showed that high-sensitive threshold showed relatively high specificity (0.452) compared with specificities by the low-sensitive threshold (0.249) or by the middle-sensitive threshold (0.358). The concordance correlation coefficients and 95% confidence intervals (in parenthesis) between the total sleep time judged by polygraph and low-sensitive, middle-sensitive, or high-sensitive accelerometer were 0.40 (0.26-0.51), 0.53 (0.38-0.65), and 0.64 (0.49-0.75), respectively. The Bland-Altman plot of the measurements showed higher agreement between the total sleep time by polygraph and by the accelerometer using the high-sensitive threshold.

CONCLUSIONS

From the result obtained in this study, the high-sensitive accelerometer showed the strongest agreement of total sleep time and sleep/wake judgment with the calculated value using the sleep polygraph.

Для цитирования: Kawada Tomoyuki, Suzuki Hiroko, Shimizu Takako, Katsumata Masao. Agreement in regard to total sleep time during a nap obtained via a sleep polygraph and accelerometer: a comparison of different sensitivity thresholds of the accelerometer.. International journal of behavioral medicine. 2012. DOI: 10.1007/s12529-011-9180-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.