MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ecoenv.2018.11.052

Медицинская библиотека · Ecotoxicology and environmental safety · 2019

Comparison of rates of direct and indirect migration of phosphorus flame retardants from flame-retardant-treated polyester curtains to indoor dust.

Tokumura Masahiro, Ogo Sayaka, Kume Kazunari, Muramatsu Kosuke, Wang Qi, Miyake Yuichi, Amagai Takashi, Makino Masakazu

СтатьяПеревод в очереди

Аннотация

In this study, the pathways for migration of phosphorus flame retardants (PFRs), tris(1,3-dichloroisopropyl) phosphate (TDCPP) and tricresyl phosphate (TCsP) which were detected from curtains often, from flame-retardant-treated polyester curtains to indoor dust were investigated. Two possible migration pathways were compared quantitatively: (1) an indirect pathway in which the PFRs in the curtains first evaporate from the curtains and are then adsorbed onto indoor dust and (2) a direct pathway in which the PFRs are directly transferred to dust placed on the curtains. The contribution of the indirect pathway was evaluated by means of emission cell tests, which showed that the area-specific emission rates from curtains treated with PFRs were 0.044 (TDCPP, Curtain 5), 0.17 (TDCPP, Curtain 8), and 0.060 (TCsP, Curtain 12) μg m-2 h-1 at 20 °C (averaged during 24 h). The contribution of the direct pathway was evaluated by measurement of the time dependence of PFR concentrations on the indoor dust placed on the curtains. These measurements indicated that PFR concentrations on the dust increased with time and that the direct migration rates of PFRs from curtains treated with PFRs were 4.4 (TDCPP, Curtain 5), 12 (TDCPP, Curtain 8), and 7.0 (TCsP, Curtain 12) μg m-2 h-1 at 20 °C (averaged during 24 h), or 71-120 times the indirect migration rate. This result suggests that the direct pathway can be expected to predominate.

Для цитирования: Tokumura Masahiro, Ogo Sayaka, Kume Kazunari, Muramatsu Kosuke, Wang Qi, Miyake Yuichi, Amagai Takashi, Makino Masakazu. Comparison of rates of direct and indirect migration of phosphorus flame retardants from flame-retardant-treated polyester curtains to indoor dust.. Ecotoxicology and environmental safety. 2019. DOI: 10.1016/j.ecoenv.2018.11.052.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.