Transcatheter closure of atrial septal defect in elderly patients with permanent atrial fibrillation.

Taniguchi Manabu, Akagi Teiji, Ohtsuki Shinichi, Okamoto Yoshio, Tanabe Yasuharu, Watanabe Nobuhisa, Nakagawa Koji, Toh Norihisa, Kusano Kengo, Sano Shunji

Оценочное исследованиеСтатьяПеревод в очереди

Аннотация

OBJECTIVES

The aim of this study is to evaluate the feasibility and efficacy of device closure of atrial septal defect (ASD) in elderly patients with permanent atrial fibrillation.

BACKGROUND

Little is known about the feasibility of device closure of ASD in those patients.

METHODS

Nine consecutive patients (mean age 68.1 years) with permanent atrial fibrillation (>1 year persistent) underwent catheter closure using the Amplatzer septal occluder. Transthoracic echocardiography and plasma B-type natriuretic peptide (BNP) level were assessed before and at 24 hours; and 1, 3, and >6 months after the closure. Before the procedure, appropriate dose of warfarin was used in all, diuretics was used in 8/9. Same amount of medications were continued after the procedure.

RESULTS

ASD could be closed in all (mean device size 27.3 mm) without hemodynamic and thromboembolic complications. New York Heart Association (NYHA) functional classification was significantly improved in all patients after device closure. No hemodynamic and thromboembolic complications were observed during the follow-up period (mean 10.6 months). Although permanent atrial fibrillation did not change in all after the procedure, resting heart rate decreased from 76.2 +/- 16.0 to 68.3 +/- 13.2 beats/min (P = 0.015). There was statistically significant improvement in right ventricular/left ventricular diameter ratio (1.08 +/- 0.16 to 0.73 +/- 0.10, P = 0.008) and plasma BNP level (183.7 +/- 90.5 to 94.6 +/- 47.4 pg/mL, P = 0.008) after >6 months device closure.

CONCLUSIONS

Even in the patients complicated with permanent fibrillation, transcatheter closure of ASD can contribute to symptomatic improvement as well as cardiac geometric remodeling.

Для цитирования: Taniguchi Manabu, Akagi Teiji, Ohtsuki Shinichi, Okamoto Yoshio, Tanabe Yasuharu, Watanabe Nobuhisa, Nakagawa Koji, Toh Norihisa, Kusano Kengo, Sano Shunji. Transcatheter closure of atrial septal defect in elderly patients with permanent atrial fibrillation.. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2009. DOI: 10.1002/ccd.21870.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.