DOI 10.2147/opth.s176025

Медицинская библиотека · Clinical ophthalmology (Auckland, N.Z.) · 2018

Macular phototoxicity after corneal cross-linking.

Barbisan Paulo Rodolfo Tagliari, Viturino Marina Gonçalves Monteiro, Souto Fernanda Maria Silveira, Tian Bo, Pacheco Pinto Roberto Damian, Quagliato Lucas Barasnevicius, Nascimento Maurício Abujamra, de Castro Rosane Silvestre, Arieta Carlos Eduardo Leite

СтатьяПеревод в очереди

Аннотация

PURPOSE: To assess potential vascular, structural, and functional changes to the macula in patients with keratoconus that underwent ultraviolet A (UVA)-riboflavin-mediated corneal collagen cross-linking (CXL) therapy.

PATIENTS AND

METHODS

Seventeen eyes from 17 patients of age 16 years or older with keratoconus undergoing CXL treatment were studied. The same eye served as its own control (before CXL vs after CXL). Eyes were evaluated in terms of best-corrected visual acuity (BCVA), refractive error, intraocular pressure, Amsler grid, retinography, fluorescein angiography, autofluorescence, and spectral domain optical coherence tomography (SD-OCT) prior to CXL and 7 and 30 days after treatment. Multifocal electroretinography (mfERG) was recorded prior to and 7 days after CXL.

RESULTS

Mean (SD) BCVA by logMAR chart was 0.47 (±0.12) pre-CXL, 0.55 (±0.15) 7 days post-CXL (P=0.57), and 0.46 (±0.10) 30 days post-CXL (P=0.87). Mean (SD) SD-OCT central macular thickness (µm) was 253.62 (±20.9) pre-CXL, 260.5 (±18.7) 7 days post-CXL (P=0.48), and 256.44 (±21.6) 30 days post-CXL (P=0.69). In 12 eyes, mfERG revealed a statistically significant increase (P=0.0353) in P1 latency (ms) of ring four from the pre-CXL period (39.45±2.05) to 7 days post-CXL (41.04±1.28) period. Regression analysis showed that the increase in P1 latency was correlated with the increase in central macular thickness (P=0.027). Furthermore, nine patients experienced a significant decrease in P1 amplitudes of rings 1 (P=0.0014), 2 (P=0.0029), 3 (P=0.0037), 4 (P=0.0014), and 5 (P=0.0012) from pre-CXL to 7 days post-CXL.

Conclusion

In this pilot study, most of the patients exhibited slight changes in their mfERG parameters and OCT thickness, despite a lack of vascular abnormalities observed on fluorescein angiography/autofluorescence imaging, no alteration in BCVA, and no reports of symptoms. These changes could, therefore, be categorized as a mild subclinical effect of the corneal cross-linking procedure.

Для цитирования: Barbisan Paulo Rodolfo Tagliari, Viturino Marina Gonçalves Monteiro, Souto Fernanda Maria Silveira, Tian Bo, Pacheco Pinto Roberto Damian, Quagliato Lucas Barasnevicius, Nascimento Maurício Abujamra, de Castro Rosane Silvestre, Arieta Carlos Eduardo Leite. Macular phototoxicity after corneal cross-linking.. Clinical ophthalmology (Auckland, N.Z.). 2018. DOI: 10.2147/opth.s176025.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.