MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jvir.2010.12.042

Медицинская библиотека · Journal of vascular and interventional radiology : JVIR · 2011

Laparoscopic demonstration of vena cava wall penetration by inferior vena cava filters in an ovine model.

Laborda Alicia, Lostalé Fernando, Rodríguez José B, Bielsa Miguel Ángel, Martínez Miguel Ángel, Serrano Carolina, Fernández Rocío, De Gregorio Miguel Ángel

СтатьяПеревод в очереди

Аннотация

PURPOSE: To verify the penetration of struts and hooks of two inferior vena cava (IVC) filters (Günther tulip retrievable filter [GTF] and Celect filter) through the vena cava wall and to assess local or systemic complications resulting from this penetration.

MATERIALS AND

METHODS

Eight IVC filters were placed in the IVC of four ewes for 30 days (1 GTF and 1 Celect filter in each ewe). Angiographic and laparoscopic examinations of the animals were performed to demonstrate the penetration through the vena cava wall, and the filters were removed under laparoscopic control. Specimens were extracted for anatomicopathological and histologic examination.

RESULTS

Two-projection cavography showed a filter leg seemingly out of the vena cava in 19 of 32 legs (59.3%). Laparoscopy showed 7 real penetrating legs (5 Celect filters and 2 GTFs) out of the 14 legs that could be identified by laparoscopy owing to technique limitations. Neither laparoscopy nor necropsy showed any sign of wall hemorrhage or other injuries. Histologic examination showed intimal remodeling and slight thickening of adventitial tissue around filter legs.

CONCLUSIONS

GTFs and Celect filters can produce a real penetration 1 month after implantation. This penetration did not lead to any complications in the IVC or surrounding tissues and did not compromise the subject's health in any of the studied cases.

Для цитирования: Laborda Alicia, Lostalé Fernando, Rodríguez José B, Bielsa Miguel Ángel, Martínez Miguel Ángel, Serrano Carolina, Fernández Rocío, De Gregorio Miguel Ángel. Laparoscopic demonstration of vena cava wall penetration by inferior vena cava filters in an ovine model.. Journal of vascular and interventional radiology : JVIR. 2011. DOI: 10.1016/j.jvir.2010.12.042.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.