Toxicological analysis of whole blood samples by means of Bond-Elut Certify columns and gas chromatography with nitrogen-phosphorus detection.

Zweipfenning P G, Wilderink A H, Horsthuis P, Franke J P, de Zeeuw R A

СтатьяПеревод в очереди

Аннотация

The application of Bond-Elut Certify solid-phase extraction columns to the systematic toxicological analysis of whole blood was evaluated. The reproducibility of the extraction was tested with thirteen drugs varying in physico-chemical properties. Analysis was performed with capillary gas chromatography with nitrogen-selective detection. The recoveries were reproducible, as long as other limiting factors, e.g., chromatographic behaviour or volatility, do not play a significant role. The effect of limiting chromatographic behaviour was studied in more detail with the more sensitive mass spectrometry with selected-ion monitoring after converting the extracted morphine into its ditrimethylsilyl derivative.

Для цитирования: Zweipfenning P G, Wilderink A H, Horsthuis P, Franke J P, de Zeeuw R A. Toxicological analysis of whole blood samples by means of Bond-Elut Certify columns and gas chromatography with nitrogen-phosphorus detection.. Journal of chromatography. A. 1994. DOI: 10.1016/0021-9673(94)85219-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.