MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.avsg.2012.07.025

Медицинская библиотека · Annals of vascular surgery · 2013

Delayed presentation of a thoracic aortic injury with a vertebral pedicle screw.

Freyrie Antonio, Gasbarrini Alessandro, Simoes Christiano Esteves, Gallitto Enrico, Gargiulo Mauro

Клинический случайСтатьяПеревод в очереди

Аннотация

Iatrogenic aortic injuries by pedicle screws are rare but serious complications of spinal fixation surgery. We report the case of a 55-year-old man who underwent surgical correction of traumatic thoracic vertebral fractures at another institution. At 6-month follow-up, computed tomography revealed a nonhealing of the fractures, and a T4 misplaced pedicle screw penetrating the descending thoracic aorta. The patient underwent open aortic repair associated with the anterior vertebral column reconstruction and posterior arthrodesis revision by a vascular and orthopedic surgery team simultaneously.

Для цитирования: Freyrie Antonio, Gasbarrini Alessandro, Simoes Christiano Esteves, Gallitto Enrico, Gargiulo Mauro. Delayed presentation of a thoracic aortic injury with a vertebral pedicle screw.. Annals of vascular surgery. 2013. DOI: 10.1016/j.avsg.2012.07.025.