m+Medelevator.RU
← Поиск публикаций
Talanta · 2022

A novel ratiometric nanoprobe based on copper nanoclusters and graphitic carbon nitride nanosheets using Ce(III) as crosslinking agent and aggregation-induced effect initiator for sensitive detection of hydrogen peroxide and glucose.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Mei He, Wang Qing, Jiang Jiahui, Zhu Xiaolei, Wang Huili, Qu Shugen, Wang Xuedong

Аннотация

Herein, glutathione-capped copper nanoclusters (CuNCs) and graphitic carbon nitride nanosheets (g-C3N4 NSs) were synthesized by a facile one-pot chemical reduction and directly thermal pyrolysis following ultrasonic exfoliation approaches, respectively. The introduction of Ce(III) (Ce3+) played dual functions in constructing a fluorescence-enhanced ratiometric nanoprobe (g-C3N4 NSs-Ce3+-CuNCs), i.e., triggering aggregation-induced emission of CuNCs and conjugating g-C3N4 NSs with CuNCs by virtue of electrostatic and coordination interactions. The as-fabricated nanohybrid displayed 460 and 625 nm dual-emitting peaks, attributing to the emission of g-C3N4 NSs and CuNCs, respectively. Upon addition of H2O2, the 625 nm emission was dramatically quenched, whereas the 460 nm emission remained nearly unchanged, thereby causing obvious color changes from purple to blue under a 365-nm UV lamp. A ratiometric fluorescent assay, based on g-C3N4 NSs-Ce3+-CuNCs, was devised for sensitive and visual detection of H2O2, which spanned the linear range of 2-100 μM with a detection limit of 0.6 μM. In the presence of glucose oxidase, the ratiometric nanoprobe could be simultaneously employed to detect glucose across the linear range of 1.6-320 μM with a detection limit of 0.48 μM. In milk and human serum samples, the fortified recoveries for H2O2 and glucose by the nanoprobe were in the range of 95.5-103.6% with RSDs <3.8%. The real detection levels for glucose are consistent with those by a standard glucometer. As such, the ratiometric nanoprobe offers a promising methodology for several practical applications, such as point-of-care diagnosis and workplace health evaluations.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты