Annals of agricultural and environmental medicine : AAEM · 2019

Non-invasive assessment of haemodynamic parameters in patients after Fontan procedure.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Gutknecht Piotr, Kwiatkowska Joanna, Wałdoch Anna, Siebert Konrad, Siebert Janusz

Аннотация

INTRODUCTION AND OBJECTIVE: Single ventricle anomaly is one of the complex congenital heart defects. A dependable non-invasive method of evaluation of Fontan circulation haemodynamics for early diagnosing unstable patients is hardly available in routine clinical practice. The aim of the study is non-invasive evaluation of the haemodynamic parameters in patients after Fontan operation.

MATERIAL AND METHODS: The study involved 11 participants (age 24.4±4.3 years) with functionally univentricular hearts after Fontan operation. Evaluation of haemodynamic parameters was performed in supine and sitting positions using the impedance cardiography method.

RESULTS: In comparative analysis, heart rate (70.1 vs.78.3 1/min; p=0.001), diastolic blood pressure (73.9 vs. 76.7 mm Hg; p=0.026), mean arterial blood pressure (84.5 vs. 88.0 mm Hg; p=0.013), systemic vascular resistance (1284.8 vs. 1334.9 dyn*s*cm-5; p=0.024), systemic vascular resistance index (2178.7 vs. 2272.8 dyn*s*cm-5*m2 ; p=0.018), pre-ejection period (124.2 vs. 136.2 ms; p=0.009), systolic time ratio (0.43 vs. 0.53; p=0.0001), and Zo (26.2 vs. 28.7 Ω; p<0.00001), were significantly higher in the sitting position. Stroke volume (75.4 vs. 68.5 ml; p=0.013), stroke index (42.7 vs. 39.0 ml*m-2; p=0.014), thoracic fluid content (38.5 vs. 35.4 1*kΩ-1; p=<0.00001), thoracic fluid content index (22.8 vs. 21.0 1*kΩ-1*m-2; p=<0.00001), and leftventricular ejection time 291.1 vs. 260.1 ms; p <0.00001, were significantly higher in the supine position.

CONCLUSIONS: In patients after Fontan procedure, impedance cardiography can be a useful tool the assessment of shortterm haemodynamic changes provoked by postural changes. Its clinical value in patients with congenital heart defects should be further investigated.