Standardized Seidel test to evaluate different sutureless cataract incision configurations.

May William N, Castro-Combs Juan, Quinto Gilherme G, Kashiwabuchi Renata, Gower Emily W, Behrens Ashley

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: To compare aqueous outflow and India ink inflow to evaluate clear corneal incisions (CCIs).

SETTING

Wilmer Eye Institute, Baltimore, Maryland, USA.

METHODS

Two 25-gauge needles connected to a salt solution bag and to a digital manometer were inserted through the limbus of human donor corneas 120 degrees apart from each other. Three 2.75 mm wide incisions were created in a different third of each cornea as follows: single-plane 1.50 mm tunnel length, single-plane 3.00 mm tunnel length, and 2-step 3.00 mm tunnel length. The Seidel test was evaluated at 5 intraocular pressures (IOPs) in the physiologic range. A masked observer evaluated the recorded tests. With a preset 10 mm Hg IOP, India ink was applied to the incision site and a sudden IOP fluctuation induced. India ink influx was outlined and measured by planimetry.

RESULTS

With the 1.5 mm single-plain incisions, all 6 globes showed inflow and outflow. With the 3.0 mm single-plain incisions, all 6 globes showed inflow and 2 showed outflow by the Seidel test. With the 3.0 mm 2-step incisions, 2 globes showed inflow and 3 had positive Seidel test results. Area and length of inflow were statistically significantly greater with the 2 single-planed incisions than with the 2-step incisions.

CONCLUSION

This human ex vivo model showed that wound deformation produced during Seidel testing might not be an accurate way to predict the risk for bacterial invasion in the early postoperative period.

Для цитирования: May William N, Castro-Combs Juan, Quinto Gilherme G, Kashiwabuchi Renata, Gower Emily W, Behrens Ashley. Standardized Seidel test to evaluate different sutureless cataract incision configurations.. Journal of cataract and refractive surgery. 2010. DOI: 10.1016/j.jcrs.2009.12.036.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.