MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1073/pnas.2315043121

Медицинская библиотека · Proceedings of the National Academy of Sciences of the United States of America · 2024

METAPHOR: Metabolic evaluation through phasor-based hyperspectral imaging and organelle recognition for mouse blastocysts and oocytes.

Parra Albert, Denkova Denitza, Burgos-Artizzu Xavier P, Aroca Ester, Casals Marc, Godeau Amélie, Ares Miguel, Ferrer-Vaquer Anna, Massafret Ot, Oliver-Vila Irene, Mestres Enric, Acacio Mònica, Costa-Borges Nuno, Rebollo Elena, Chiang Hsiao Ju, Fraser Scott E, Cutrale Francesco, Seriola Anna, Ojosnegros Samuel

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Only 30% of embryos from in vitro fertilized oocytes successfully implant and develop to term, leading to repeated transfer cycles. To reduce time-to-pregnancy and stress for patients, there is a need for a diagnostic tool to better select embryos and oocytes based on their physiology. The current standard employs brightfield imaging, which provides limited physiological information. Here, we introduce METAPHOR: Metabolic Evaluation through Phasor-based Hyperspectral Imaging and Organelle Recognition. This non-invasive, label-free imaging method combines two-photon illumination and AI to deliver the metabolic profile of embryos and oocytes based on intrinsic autofluorescence signals. We used it to classify i) mouse blastocysts cultured under standard conditions or with depletion of selected metabolites (glucose, pyruvate, lactate); and ii) oocytes from young and old mouse females, or in vitro-aged oocytes. The imaging process was safe for blastocysts and oocytes. The METAPHOR classification of control vs. metabolites-depleted embryos reached an area under the ROC curve (AUC) of 93.7%, compared to 51% achieved for human grading using brightfield imaging. The binary classification of young vs. old/in vitro-aged oocytes and their blastulation prediction using METAPHOR reached an AUC of 96.2% and 82.2%, respectively. Finally, organelle recognition and segmentation based on the flavin adenine dinucleotide signal revealed that quantification of mitochondria size and distribution can be used as a biomarker to classify oocytes and embryos. The performance and safety of the method highlight the accuracy of noninvasive metabolic imaging as a complementary approach to evaluate oocytes and embryos based on their physiology.

Для цитирования: Parra Albert, Denkova Denitza, Burgos-Artizzu Xavier P, Aroca Ester, Casals Marc, Godeau Amélie, Ares Miguel, Ferrer-Vaquer Anna, Massafret Ot, Oliver-Vila Irene, Mestres Enric, Acacio Mònica, Costa-Borges Nuno, Rebollo Elena, Chiang Hsiao Ju, Fraser Scott E, Cutrale Francesco, Seriola Anna, Ojosnegros Samuel. METAPHOR: Metabolic evaluation through phasor-based hyperspectral imaging and organelle recognition for mouse blastocysts and oocytes.. Proceedings of the National Academy of Sciences of the United States of America. 2024. DOI: 10.1073/pnas.2315043121.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.