MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.radonc.2018.05.007

Медицинская библиотека · Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology · 2018

Respiratory motion of lymph node stations in pancreatic cancer: Analyses using contrast-enhanced four-dimensional computed tomography.

Takahashi Shigeo, Anada Masahide, Kinoshita Toshifumi, Shibata Toru

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND AND PURPOSE: Data regarding respiratory motion of lymph node (LN) stations in pancreatic cancer is limited. Therefore, we assessed their respiratory motion using contrast-enhanced four-dimensional-computed tomography (CE-4DCT).

MATERIAL AND

METHODS

We evaluated respiratory motion in 18 pancreatic cancer patients. We selected LN stations around major arteries which were visible on CE-4DCT images. This included the common hepatic, celiac, splenic, and superior mesenteric stations. Two radiation oncologists individually delineated the gross tumor volume (GTV) and the LN stations as observers 1 and 2.

RESULTS

The respiratory motion of the celiac (median, 3.9 mm each for both observers) and superior mesenteric (median, 4.5 and 5.0 mm for observers 1 and 2, respectively) stations in the craniocaudal (CC) directions was significantly smaller than that of the GTV (median, 8.9 and 7.8 mm for observers 1 and 2, respectively). The respiratory motion of the common hepatic station (median, 3.8 and 3.6 mm for observers 1 and 2, respectively) in the anterior-posterior (AP) direction was significantly larger than that of the GTV (median, 2.8 and 2.2 mm for observers 1 and 2, respectively).

CONCLUSIONS

We observed significant differences in respiratory motion between the GTV and the LN stations in pancreatic cancer.

Для цитирования: Takahashi Shigeo, Anada Masahide, Kinoshita Toshifumi, Shibata Toru. Respiratory motion of lymph node stations in pancreatic cancer: Analyses using contrast-enhanced four-dimensional computed tomography.. Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology. 2018. DOI: 10.1016/j.radonc.2018.05.007.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.