MedElevator Войти в исследования
← Поиск публикаций

DOI 10.23736/s0392-9590.18.03928-7

Медицинская библиотека · International angiology : a journal of the International Union of Angiology · 2018

Evaluation of three different devices to reduce stasis edema in poorly mobile nursing home patients.

Benigni Jean-Patrick, Uhl Jean-François, Balet Florence, Filori Pascal, Chahim Maxime

СтатьяРандомизированное исследованиеПеревод в очереди

Аннотация

BACKGROUND

Prolonged immobility in the sitting position in the elderly is known to produce venous stasis with leg edema and possible skin changes. Compression stockings are often applied for this clinical problem. There is few experienced nursing staff available to supervise the difficult task of stocking application.

METHODS

The authors have researched other effective and simple devices that may be suitable alternatives. This article reports the results of three different devices to reduce leg edema, as measured by reduction in leg volume: an electro-stimulation device, an adjustable compression Velcro® wrap and a short stretch bandage, each tested over a two-hour period.

RESULTS

In this randomized pilot study including 38 patients, the authors observed no difference in leg volume following electro-stimulation (Veinoplus®). They noted a significant reduction in leg volume following use of the other two devices, more with the adjustable Velcro® wrap compression (Circaid Juxtafit®) than with the short stretch bandage (Rosidal K®). Measurement of the interface pressures created by these two devices and also assessing the stiffness created by applying each device for two hours confirm that pressure is more important than stiffness in the reduction of edema in these particular patients.

CONCLUSIONS

This pilot study is to be added to the results of previous published studies showing the efficacy in reducing leg edema of Velcro® adjustable compression wrap and its ease of use.

Для цитирования: Benigni Jean-Patrick, Uhl Jean-François, Balet Florence, Filori Pascal, Chahim Maxime. Evaluation of three different devices to reduce stasis edema in poorly mobile nursing home patients.. International angiology : a journal of the International Union of Angiology. 2018. DOI: 10.23736/s0392-9590.18.03928-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.