Foot & ankle international · 2004
Torque resistance after fixation of Jones fractures with intramedullary screws.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Horst Frank, Gilbert Brett J, Glisson Richard R, Nunley James A
Аннотация
BACKGROUND: Intramedullary screws frequently are used for fixation of Jones fractures of the fifth metarsal. While the ability of intramedullary screw fixation in fifth metatarsals to resist bending and tensile forces is well known, the ability to withstand torsion has not been studied. This paper compares the torsional stiffness of Jones fractures treated with 6.5-mm short- threaded intramedullary screws to those treated with 5.0-mm cannulated short-threaded intramedullary screws.
METHODS: Nine fresh-frozen, matched pairs of cadaver fifth metatarsals had an acute Jones fracture simulated with an osteotomy. They were stabilized with intramedullary screws and then loaded to failure.
RESULTS: The torsional stiffness of the metatarsals fixed with the 6.5-mm did not differ significantly from that using 5.0-mm screws. However, to achieve stability, the 5.0-mm screw had to be long enough to reach the metatarsal head and neck. This tended to straighten the normally curved fifth metatarsal bone and caused lateral gapping at the fracture site.
CONCLUSION: Both 5.0-mm or 6.5-mm screws provide equal torsional rigidity, but 5.0-mm screws may need to be longer, which could potentially straighten the fifth metatarsal shaft in patients who have a curved fifth metatarsal.
METHODS: Nine fresh-frozen, matched pairs of cadaver fifth metatarsals had an acute Jones fracture simulated with an osteotomy. They were stabilized with intramedullary screws and then loaded to failure.
RESULTS: The torsional stiffness of the metatarsals fixed with the 6.5-mm did not differ significantly from that using 5.0-mm screws. However, to achieve stability, the 5.0-mm screw had to be long enough to reach the metatarsal head and neck. This tended to straighten the normally curved fifth metatarsal bone and caused lateral gapping at the fracture site.
CONCLUSION: Both 5.0-mm or 6.5-mm screws provide equal torsional rigidity, but 5.0-mm screws may need to be longer, which could potentially straighten the fifth metatarsal shaft in patients who have a curved fifth metatarsal.