BACKGROUND

Nonaspirin, nonsteroidal anti-inflammatory drugs (NANSAIDs) have been associated with arterial thromboembolic events in the general population. Our objective was to determine the prevalence of NANSAID use in patients diagnosed with cryptogenic emboli or paradoxical embolic events from a patent foramen ovale (PFO) or atrial septal defect (ASD) compared with a control population with an incidental PFO/ASD and no history of embolic events.

METHODS

We performed a retrospective case-control study of 90 age-matched patients to assess the association of NANSAIDs with cryptogenic arterial embolic events in patients with and without a history of PFO/ASD. Odds ratios (ORs) were obtained by chi2 analysis. Multivariate analysis was conducted with a logistical regression method.

RESULTS

Patients with cryptogenic embolic events had a high prevalence of prescription NANSAID use regardless of the presence of a PFO/ASD and were far more likely to have a history of NANSAID use than those with an incidentally discovered PFO/ASD and no history of arterial emboli (OR 4.30, 95% confidence interval 1.14-13.07, p = 0.01).

CONCLUSIONS

Many patients previously diagnosed with paradoxical emboli may be experiencing the prothrombotic effects of NANSAIDs rather than a paradoxical mechanism for their arterial embolic event.

Для цитирования: Ferguson Michael A, Mackay Steven M, Ramchandani Suneil R, Thurber John S, Curran Michael J, DeGraba Thomas J. Cryptogenic emboli in patients with patent foramen ovale or atrial septal defect associated with the use of nonsteroidal anti-inflammatory drugs.. Cardiology. 2008. DOI: 10.1159/000164269.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.